11
The surface temperature is an average value and varies somewhat depending
on the material and the thickness. Denser (harder) wood insulates less than
softer wood, which increases the surface temperature. Also, the thinner the loor,
the higher the surface temperature.
Two sensors are required for over heating protection: a room sensor (sensor A)
and an over heating protection sensor (sensor B).
Program menu
PROGRAM
A smart way of saving energy is to adapt the heating to suit the needs through-
out the day and, for example, lower the temperature when there is nobody
home. There are four diferent ways of lowering the temperature: two preset pro-
grams for home or oice environments, one program for personal settings and
a frost protection program. There is no need to consider the heating time when
programming since the thermostat has an adaptive function that applies this
automatically.
The programs are in the
MAIN MENU
under
PROGRAM
. To change program, browse
using
or
and select using
. The manual program is the factory setting, i.e.
you set the required temperature (set point) and the thermostat maintains that
temperature.
Program for home environment
HOME
The temperature is lowered automatically by 5°C at the following times:
Monday–Friday 08:30–15:00 and every day between 23:00–05:00.
The home environment program is under
PROGRAM
in the
MAIN MENU
. Select
HOME
using
and a message is shown for two seconds to conirm that the program
has been activated. You can then see in display mode that the program is active
when
HOME
is shown on the second row.
The temperature can be set b5°C and +45°C. The thermostat works from
the temperature that is set in the manual program where the factory setting is
+22°C. If you change the temperature in the manual program, or the set point in
the
TEMP
menu, the thermostat works from the new temperature, and lowers the
temperature by +5°C from the newly set temperature.
Program for oice environment
OFFICE
The temperature is lowered automatically by 5°C apart from at the following times:
Monday–Friday 06:00–18:00.
The oice environment program is under
PROGRAM
in the
MAIN MENU
. Select
OFFICE
using
and a message is shown for two seconds to conirm that the program
has been activated. You can then see in display mode that the program is active
when
OFFICE
is shown on the second row.