2. Basic commands
Transmit
Data[9]
\x55
Data[10]
\x56
Data[11]
\x29
Data[12]
\x00
Checksum
\x26
Stop
\xff
Receive (Answer)
Start
\xfe
Projector address
\x01
Command[0]
\x00
Command[1]
\x06
Data
error char strings
Checksum
\x..
Stop
\xff
Desktop error strings ( if present)
The operating system (Windows
TM
) uses a yellow notification area to display errors and messages. These messages appear in the
lower right corner of the desktop.
The acknowledge bytes (c data bytes ,...) are followed by a character string representing the actual message or error
displayed.
An example is the error
“No image file found”
that can be generated when selecting a inactive (not present) source.
The character string sent is the following :
\x2b\x00\xff\xff\xff\xf1\x00\x4e\x00\x6f\x00\x20\x00\x49\x00\x6d\x00\x61\x00\x67\x00\x65\x00\x66\x00\x69\x00
Note that each character is followed by the \x00, the string being also ended with \x00.
R59770077 RS 232 SERIAL COMMUNICATIONS FOR ICON H250/400 16/02/2007
71
Summary of Contents for iCon H250
Page 1: ...RS 232 Serial Communications for iCon H250 400 User Manual Basic R59770077 00 16 02 2007...
Page 4: ......
Page 100: ...2 Basic commands 96 R59770077 RS 232 SERIAL COMMUNICATIONS FOR ICON H250 400 16 02 2007...