2. Basic commands
2.16 Freeze, Read
Description
Reads whether the projected image is frozen or not.
Command
Command [0]
\x21
Command [1]
\x23
Returned Data
Data [0] = unsigned byte
byte value:
\x00
= OFF ;
\x01
= ON
Example
Reads the Freeze function, being
\x00
= OFF
Transmit
Start
\xfe
Projector address
\x01
Command[0]
\x21
Command[1]
\x23
Checksum
\x45
Stop
\xff
Receive (acknowledge)
Start
\xfe
Projector address
\x01
Command[0]
\x00
Command[1]
\x06
Checksum
\x07
Stop
\xff
Receive (awnser)
Start
\xfe
Projector address
\x01
Command[0]
\x21
Command[1]
\x23
Data[0]
\x00
Checksum
\x45
Stop
\xff