2. Basic commands
2.25 Filmmode detection, Read
Description
Reads whether the Filmmode detection is enabled or not
Command
Command [0]
\x21
Command [1]
\xa1
Returned Data
Data [0] = unsigned byte
byte value:
\x00
= OFF ;
\x01
= ON
Example
Reads the Automatic startup, being
\x00
= OFF
Transmit
Start
\xfe
Projector address
\x01
Command[0]
\x21
Command[1]
\xa1
Checksum
\xc3
Stop
\xff
Receive (acknowledge)
Start
\xfe
Projector address
\x01
Command[0]
\x00
Command[1]
\x06
Checksum
\x07
Stop
\xff
Receive (awnser)
Start
\xfe
Projector address
\x01
Command[0]
\x21
Command[1]
\xa1
Data[0]
\x00
Checksum
\xc3
Stop
\xff
R59770077 RS 232 SERIAL COMMUNICATIONS FOR ICON H250/400 16/02/2007
95
Summary of Contents for iCon H250
Page 1: ...RS 232 Serial Communications for iCon H250 400 User Manual Basic R59770077 00 16 02 2007...
Page 4: ......
Page 100: ...2 Basic commands 96 R59770077 RS 232 SERIAL COMMUNICATIONS FOR ICON H250 400 16 02 2007...
Page 122: ...3 Advanced commands 118 R59770077 RS 232 SERIAL COMMUNICATIONS FOR ICON H250 400 16 02 2007...