2. Basic commands
2.6.33
Phase, Write
Description
Writes a new Phase value to the projector
Command
Command [0]
\x20
Command [1]
\x06
Data
Data [0] = Phase value
value = unsigned byte
Example
Writes a new Phase value of
\x1a
to the projector
Transmit
Start
\xfe
Projector address
\x01
Command[0]
\x20
Command[1]
\x06
Data
\x1a
Checksum
\x41
Stop
\xff
Receive (acknowledge)
Start
\xfe
Projector address
\x01
Command[0]
\x00
Command[1]
\x06
Checksum
\x07
Stop
\xff
R59770077 RS 232 SERIAL COMMUNICATIONS FOR ICON H250/400 16/02/2007