1. Serial communication basics
End of process (EOP)
When the end of process command is activated, an EOP is send after the ACK command to signify the completion of the process.
for more information about this, see the EOP command.
Note
Any command byte, data byte or checksum byte that equals
\x80, \xfe, \xff
has to be converted !
1.
Transmission
- instead of
\x80
, send
\x80
followed by
\x00
- instead of
\xfe
, send
\x80
followed by
\x7e
- instead of
\xff
, send
\x80
followed by
\x7f
2.
Reception
- replace
\x80
followed by
\x00
with
\x80
- replace
\x80
followed by
\x7e
with
\xfe
- replace
\x80
followed by
\x7f
with
\xff