21. Troubleshooting
Error
code
Description
Error
Warning
Caused by
Action
7954
VTEC voltage
high
No
Yes
supply voltage for DMD cooling too
high
If problem persists, call a quali
fi
ed
service engineer
7953
VMTR voltage
low
No
Yes
supply voltage for motors too low
If problem persists, call a quali
fi
ed
service engineer
7952
VMTR voltage
high
No
Yes
supply voltage for motors too high
If problem persists, call a quali
fi
ed
service engineer
7945
5V voltage low
No
Yes
supply voltage for electronics too
low
If problem persists, call a quali
fi
ed
service engineer
7944
5V voltage high
No
Yes
supply voltage for electronics too
high
If problem persists, call a quali
fi
ed
service engineer
7943
5V FIB voltage
low
No
Yes
supply voltage for engine
electronics too low
If problem persists, call a quali
fi
ed
service engineer
7942
5V FIB voltage
high
No
Yes
supply voltage for engine
electronics too high
If problem persists, call a quali
fi
ed
service engineer
7941
5V PMP
voltage low
No
Yes
supply voltage for drawer
electronics too low
If problem persists, call a quali
fi
ed
service engineer
7940
5V PMP
voltage high
No
Yes
supply voltage for drawer
electronics too high
If problem persists, call a quali
fi
ed
service engineer
7939
Prism
No
Yes
projection lens to close to prism
move lens away from prism (up
and/or right)
7938
Lamp not
inserted well
Yes
No
lamp module not correctly inserted
reinsert lamp module and screw
fi
rmly
7937
Water
fl
ow
Yes
No
bad or no water
fl
ow in cooling
circuit
If problem persists, call a quali
fi
ed
service engineer
7936
Tilt
No
Yes
tilt angle is out of speci
fi
cations
Correct projection installation.
Change the tilting so that the
tilt angle becomes within the
speci
fi
cations.
7935
Engine not well
inserted
Yes
No
engine is not correctly inserted
If problem persists, call a quali
fi
ed
service engineer
7934
FIB not
inserted well
Yes
No
formatter interface board is not
correctly inserted
If problem persists, call a quali
fi
ed
service engineer
7931
PFC HS high
temp
Yes
Yes
high temperature on smps
check if air slot are free; clean air
fi
lters If problem persists, call a
quali
fi
ed service engineer
7929
SMPS HS high
temp
Yes
Yes
high temperature on smps
check if air slot are free; clean air
fi
lters If problem persists, call a
quali
fi
ed service engineer
7928
Overtemp
Yes
No
extreme overheating of dmd’s or
lamp
If problem persists, call a quali
fi
ed
service engineer
7927
fan speed
mains input
too low
Yes
Yes
fan is not running or is running too
slow
If problem persists, call a quali
fi
ed
service engineer
7926
fan speed
mains input
high
-
Yes
8000
Opening
shutter failed
No
Yes
If problem persists, call a quali
fi
ed
service engineer
8001
Closing shutter
failed
No
Yes
If problem persists, call a quali
fi
ed
service engineer
8002
Lamp
EEPROM
No
Yes
If problem persists, call a quali
fi
ed
service engineer
9000
Scaler unit
failed
Yes
-
Initialization of the scaler failed
If problem persists, call a quali
fi
ed
service engineer
9198
Scaler pixel
clock too high
Yes
-
BW or refresh rate of input source
too high
218
R59770179 FLM R22+ 15/03/2010
Summary of Contents for FLM R22+
Page 1: ...FLM R22 User guide R9004500 R59770179 04 15 03 2010...
Page 14: ...1 Safety 10 R59770179 FLM R22 15 03 2010...
Page 46: ...5 Connections 42 R59770179 FLM R22 15 03 2010...
Page 62: ...7 Start up of the Adjustment Mode 58 R59770179 FLM R22 15 03 2010...
Page 72: ...8 Input menu 68 R59770179 FLM R22 15 03 2010...
Page 98: ...9 Image menu 94 R59770179 FLM R22 15 03 2010...
Page 114: ...10 Layout menu Image 10 65 Image 10 66 Image 10 67 110 R59770179 FLM R22 15 03 2010...
Page 120: ...11 Lamp menu 116 R59770179 FLM R22 15 03 2010...
Page 148: ...12 Alignment menu 144 R59770179 FLM R22 15 03 2010...
Page 168: ...13 Projector control 164 R59770179 FLM R22 15 03 2010...
Page 184: ...14 Service menu 180 R59770179 FLM R22 15 03 2010...
Page 204: ...17 Removal of the projector covers 200 R59770179 FLM R22 15 03 2010...
Page 208: ...18 Dimensions 204 R59770179 FLM R22 15 03 2010...
Page 216: ...20 DMX chart 212 R59770179 FLM R22 15 03 2010...
Page 224: ...21 Troubleshooting 220 R59770179 FLM R22 15 03 2010...
Page 232: ...22 Specifications 228 R59770179 FLM R22 15 03 2010...
Page 234: ...23 Order information 230 R59770179 FLM R22 15 03 2010...