21. Troubleshooting
Error
code
Description
Error
Warning
Caused by
Action
7694
Red front DMD
temp high
Yes
Yes
High temperature on red DMD
Check if air slots are free.
Clean air
fi
lters.
If problem persists, call a quali
fi
ed
service engineer
7693
Red front DMD
temp open
Yes
Yes
Temperature sensor on Red DMD
not connected
Call a quali
fi
ed service engineer
7692
Red front DMD
temp short
Yes
Yes
Temperature sensor on Red DMD
shorted
Call a quali
fi
ed service engineer
7691
Green front
DMD temp low
No
Yes
Low temperature on green DMD
Switching on the lamp will heat up
the DMD
7690
Green front
DMD temp high
Yes
Yes
High temperature on green DMD
Check if air slots are free.
Clean air
fi
lters.
If problem persists, call a quali
fi
ed
service engineer
7689
Green front
DMD temp
open
Yes
Yes
Temperature sensor on green DMD
not connected
Call a quali
fi
ed service engineer
7888
Green front
DMD temp
short
Yes
Yes
Temperature sensor on green DMD
shorted
Call a quali
fi
ed service engineer
7687
Blue front DMD
temp low
Yes
-
Low temperature on blue DMD
Switching on the lamp will heat up
the DMD
7686
Blue front DMD
temp high
Yes
Yes
High temperature on blue DMD
Check if air slots are free.
Clean air
fi
lters.
If problem persists, call a quali
fi
ed
service engineer
7685
Blue front DMD
temp open
Yes
Yes
Temperature sensor on blue DMD
not connected
Call a quali
fi
ed service engineer
7684
Blue front DMD
temp short
Yes
Yes
Temperature sensor on blue DMD
shorted
Call a quali
fi
ed service engineer
7676
Front block
temp high
Yes
Yes
High temperature on front DMD
cooling block
Check if air slots are free.
Clean air
fi
lters.
If problem persists, call a quali
fi
ed
service engineer
7675
Front block
temp open
Yes
Yes
Temperature sensor on front cooling
block not connected
Call a quali
fi
ed service engineer
7674
Front block
temp short
Yes
Yes
Temperature sensor on front cooling
block shorted
Call a quali
fi
ed service engineer
7672
Red block temp
high
Yes
Yes
High temperature on red DMD
cooling block
Check if air slots are free.
Clean air
fi
lters.
If problem persists, call a quali
fi
ed
service engineer
7671
Red block temp
open
Yes
Yes
Temperature sensor on red DMD
cooling block not connected
Call a quali
fi
ed service engineer
7670
Red block temp
short
Yes
Yes
Temperature sensor on red DMD
cooling block shorted
Call a quali
fi
ed service engineer
7668
Green block
temp high
Yes
Yes
High temperature on green DMD
cooling block
Check if air slots are free.
Clean air
fi
lters.
If problem persists, call a quali
fi
ed
service engineer
7667
Green block
temp open
Yes
Yes
Temperature sensor on green DMD
cooling block not connected
Call a quali
fi
ed service engineer
7666
Green block
temp short
Yes
Yes
Temperature sensor on green DMD
cooling block shorted
Call a quali
fi
ed service engineer
R59770179 FLM R22+ 15/03/2010
215
Summary of Contents for FLM R22+
Page 1: ...FLM R22 User guide R9004500 R59770179 04 15 03 2010...
Page 14: ...1 Safety 10 R59770179 FLM R22 15 03 2010...
Page 46: ...5 Connections 42 R59770179 FLM R22 15 03 2010...
Page 62: ...7 Start up of the Adjustment Mode 58 R59770179 FLM R22 15 03 2010...
Page 72: ...8 Input menu 68 R59770179 FLM R22 15 03 2010...
Page 98: ...9 Image menu 94 R59770179 FLM R22 15 03 2010...
Page 114: ...10 Layout menu Image 10 65 Image 10 66 Image 10 67 110 R59770179 FLM R22 15 03 2010...
Page 120: ...11 Lamp menu 116 R59770179 FLM R22 15 03 2010...
Page 148: ...12 Alignment menu 144 R59770179 FLM R22 15 03 2010...
Page 168: ...13 Projector control 164 R59770179 FLM R22 15 03 2010...
Page 184: ...14 Service menu 180 R59770179 FLM R22 15 03 2010...
Page 204: ...17 Removal of the projector covers 200 R59770179 FLM R22 15 03 2010...
Page 208: ...18 Dimensions 204 R59770179 FLM R22 15 03 2010...
Page 216: ...20 DMX chart 212 R59770179 FLM R22 15 03 2010...
Page 224: ...21 Troubleshooting 220 R59770179 FLM R22 15 03 2010...
Page 232: ...22 Specifications 228 R59770179 FLM R22 15 03 2010...
Page 234: ...23 Order information 230 R59770179 FLM R22 15 03 2010...