4. Lamp & Lamp House
Image 4-11
3. Install the lamp cathode adaptor (A) upon the xenon bulb lamp (L) as illustrated. Use torque
2,5 Nm
(1,8 lbf*ft) to fasten the
fi
xation screw (S) of the adapter. Use for that a torque wrench with a 5 mm Allen socket. Make sure that there is full contact
between the cathode adapter and the lamp base.
Note:
In case of a lamp replacement you have to reuse the adaptor from the xenon bulb lamp which you want to replace.
S
L
A
2,5 Nm
Image 4-12
4. Install the anode wire lug (L) upon the anode socket (S). Hold fast the nut N1 with an open-end wrench while fastening the nut
N2 with a torque of
9 Nm
(6,6 lbf*ft) using a torque wrench. Ensure that at both sides of the wire lug L a plane washer (W1 &
W2) is present.
Note:
The anode socket is located just below the UV blocker and can easily be removed from the lamp house. In case of a lamp
replacement you have to reuse the anode socket which is connected to the xenon bulb lamp which you want to replace.
36
R59770242 DP-1200 06/01/2009
Summary of Contents for DP-1200
Page 1: ...DP 1200 Installation manual R59770242 02 06 01 2009 ...
Page 12: ...1 Safety 8 R59770242 DP 1200 06 01 2009 ...
Page 20: ...2 General 16 R59770242 DP 1200 06 01 2009 ...
Page 29: ...3 Physical Installation 1 2 3 5 4 7 6 Image 3 11 R59770242 DP 1200 06 01 2009 25 ...
Page 60: ...5 Lenses lens holder 56 R59770242 DP 1200 06 01 2009 ...
Page 78: ...8 Starting up 74 R59770242 DP 1200 06 01 2009 ...
Page 86: ...9 Projector registration Image 9 9 Add new owner 82 R59770242 DP 1200 06 01 2009 ...
Page 104: ...10 Removal and installation of projector covers 100 R59770242 DP 1200 06 01 2009 ...
Page 128: ...A Specifications 124 R59770242 DP 1200 06 01 2009 ...
Page 129: ...B Order Info B ORDER INFO Overview Spare part order info R59770242 DP 1200 06 01 2009 125 ...