4. Lamp & Lamp House
Image 4-7
4. Slide the white anode socket, which is connected via a thick wire with the xenon bulb lamp, upwards away from its position and
then remove the xenon bulb lamp with anode socket from the lamp house.
Image 4-8
5. Place the xenon bulb lamp into a protective container or wrap a protective cloth around the xenon bulb lamp.
6. Remove the anode wire lug from the anode socket. Use for that two open ended spanners of 17 mm. Hold fast the nut N1 with
one spanner while releasing the nut N2 with the other spanner. Note that a plane washer (W1 & W2) is provided on both sides
of the anode wire lug (L).
L
N2
S
W1
W2
N1
N1
N2
Image 4-9