3. Physical Installation
3.3
Connecting the projector with the power net
W
ARNING
:
The total electrical installation should be protected by an appropriate rated and readily accessi-
ble disconnect switch, circuit breakers and ground fault current interrupters. The installation shall be done
according to the local electrical installation codes.
C
AUTION
:
ALL POWER CONNECTIONS to the DP-1200 projector are made to the three-terminal strip located
in a sealed compartment behind the rear cover of the projector.
C
AUTION
:
The cross-sectional area of the conductors in the Power Supply Cord shall be not less than 4 mm
2
or AWG 10
Necessary tools
•
Flat screw driver.
•
Phillips screw driver PH2.
Necessary parts
•
Two cable ties.
•
Certi
fi
ed AC power supply cord 4.0 mm², 10AWG, min. 300V.
How to connect the main AC power with the DP-1200 projector?
1. Remove the rear cover and lamp cover of the projector.
2. Remove the cover of the main AC compartment by releasing the three captive dumb screws.
Image 3-6
3. Guide the AC power cord through the cable gland and connect the wires to the 3-terminal strip as illustrated.
Warning:
Always connect
fi
rst the PE wire.
PE
Image 3-7
22
R59770242 DP-1200 06/01/2009
Summary of Contents for DP-1200
Page 1: ...DP 1200 Installation manual R59770242 02 06 01 2009 ...
Page 12: ...1 Safety 8 R59770242 DP 1200 06 01 2009 ...
Page 20: ...2 General 16 R59770242 DP 1200 06 01 2009 ...
Page 29: ...3 Physical Installation 1 2 3 5 4 7 6 Image 3 11 R59770242 DP 1200 06 01 2009 25 ...
Page 60: ...5 Lenses lens holder 56 R59770242 DP 1200 06 01 2009 ...
Page 78: ...8 Starting up 74 R59770242 DP 1200 06 01 2009 ...
Page 86: ...9 Projector registration Image 9 9 Add new owner 82 R59770242 DP 1200 06 01 2009 ...
Page 104: ...10 Removal and installation of projector covers 100 R59770242 DP 1200 06 01 2009 ...
Page 128: ...A Specifications 124 R59770242 DP 1200 06 01 2009 ...
Page 129: ...B Order Info B ORDER INFO Overview Spare part order info R59770242 DP 1200 06 01 2009 125 ...