X(mm)
Horizontal distance from the surface visible in the selected pixel to the center of the image, along the X axis.
Y(mm)
Horizontal distance from the surface visible in the selected pixel to the center of the image, along the Y axis.
Z(mm)
Depth from the surface visible in the selected pixel to the face of the sensor.
Cursor(x,y)
Pixel coordinates of the selected pixel on the image sensor chip.
4.2 Connection Pane
Use the
Connection
pane parameters to change the sensor IP address and to connect to the sensor.
Figure 12. Sensor Pane
The default IP address for the ZMX sensor is 192.168.0.10.
The Banner 3D Configuration software remembers the IP address of the last connected sensor. The software also searches
the local Ethernet subnetwork to find any available sensors. These sensors are listed in the
Connection
pane.
Hover over
to view sensor name, serial number, MAC address, Gateway, firmware version, etc. To change a sensor’s IP
address, click
.
To connect to a sensor, enter the IP address of the desired ZMX sensor into the
Sensor IP Address
field, then click
next
to the IP address. Alternately, locate the IP address of the desired sensor in the list of discovered sensors, then click
in
the
Action
column.
The model number of the sensor also displays.
To disconnect from a sensor, click
.
Click
to reboot a connected sensor.
4.3 Sensor Controls Pane
Use the
Sensor Controls
pane parameters to set the trigger mode and illumination output.
Figure 13. Sensor Controls Pane
ZMX Series 3D Time of Flight Sensor
www.bannerengineering.com - Tel: + 1 888 373 6767
13