Sensor-Specific Data
Data Size
Standard Deviation Saturation
32-bit float
Standard Deviation Intensity
32-bit float
Note: Average Color Sensor data that does not apply to the selected color space has a result of 0. For
example, if the HSI color space is selected, the Red, Green, and Blue data will have a result of 0.
Table 75: Color Compare Sensor ID = 7
Sensor-Specific Data
Data Size
Color Difference
16
‐
bit Integer
Intensity Difference
16
‐
bit Integer
Table 76: Color Area Sensor ID = 8
Sensor-Specific Data
Data Size
Area Count
32
‐
bit Integer
Area Range Minimum
32
‐
bit Integer
Area Range Maximum
32
‐
bit Integer
The Custom Map Submodule contains a user-defined map of sensor output data. There are six versions with 16, 32, 64,
128, 256, and 512 bytes, depending on the size of the output data.
Table 77: Custom Map Submodule
Submodule
PLC Input Data
PLC Output Data
Name
Ident No.
Name
Type
Name
Type
16-Byte Custom Map
0x00028
Frame number
Unsigned32
Not applicable
Not applicable
User-mapped Sensor Result Data Block
16-byte OctetString
32-Byte Custom Map
0x00029
Frame number
Unsigned32
Not applicable
Not applicable
User-mapped Sensor Result Data Block
32-byte OctetString
64-Byte Custom Map
0x00030
Frame number
Unsigned32
Not applicable
Not applicable
User-mapped Sensor Result Data Block
64-byte OctetString
128-Byte Custom Map
0x00031
Frame number
Unsigned32
Not applicable
Not applicable
User-mapped Sensor Result Data Block
128-byte OctetString
256-Byte Custom Map
0x00032
Frame number
Unsigned32
Not applicable
Not applicable
User-mapped Sensor Result Data Block
256-byte OctetString
512-Byte Custom Map
0x00033
Frame number
Unsigned32
Not applicable
Not applicable
User-mapped Sensor Result Data Block
512-byte OctetString
Configure a Custom Industrial Ethernet (IE) Map
1. Enable the Custom Map by selecting Custom on the drop-down list.
iVu Plus TG and Color Gen2 Image Sensors
www.bannerengineering.com - Tel: + 1 888 373 6767
177