5. Place the filter into the filter cap and press the cap onto the lens.
6. After the filter is installed, place the focusing window back into the housing while inserting the locking clip into the
groove as shown.
C
B
Groove
Figure 11. Locking Clip in the Groove
7. Press the focusing window onto the housing to make sure that there is no gap between the window and the
housing. Rotate the window counter-clockwise at least two turns.
8. Replace the locking tab screw but do not tighten it until you have set up and focused the iVu again.
Installing a Filter on the C-Mount Lens Model
To install a filter on the iVu with C-Mount lens, use the illustration as a guide and follow the steps listed below.
CAUTION: Failure to follow these instructions may cause damage to your iVu.
D
C
A
B
E
C
A
C-Mount Lens
B
Lens Enclosure
C
Retainer Ring
D
Filter
E
Filter Retainer Ring Tool
Figure 12. C-Mount Lens Model Components
Note: Filter kits are available separately.
1. Remove the lens enclosure and C-mount lens.
2. Install filter behind the retainer ring. Make sure it is fully seated.
3. Using the provided retainer ring tool, thread the retainer ring into the iVu until it firmly seats the filter.
4. Replace the lens and lens enclosure on the iVu.
4.4 Install the Software
Important: Administrative rights are required to install the Vision Manager software.
1. Download the latest version of the software from
2. Navigate to and open the downloaded file.
3. Click Next to begin the installation process.
4. Confirm the software destination and availability for users and click Next.
5. Click Install to install the software.
6. Depending on your system settings, a popup window may appear prompting to allow Vision Manager to make
changes to your computer. Click Yes.
7. Click Close to exit the installer.