Table 83: Text Response 32-byte Submodule (Ident 0x00051)
PLC Input Data Name
Input Data Type
Flag indicating when to Command ACK
Unsigned16
Numeric Command Status
Unsigned16
16-bit integer command response
Unsigned16
32-bit integer command response
Unsigned32
Floating-point command argument
Float32
Length-of-Command/Response string
Unsigned32
32-character command response string
32-byte OctetString
Flag Indicating When to Command ACK
Bit Position for Cyclic Input
Data
Function
Bit 0
Command Channel Command
Acceptance Acknowledgement
Bit 15
Command Execution Error
PLC Output Data Name
Output Data Type
Not applicable
Not applicable
Table 84: Text Response 64-byte Submodule (Ident 0x00052)
PLC Input Data Name
Input Data Type
Flag indicating when to Command ACK
Unsigned16
Numeric Command Status
Unsigned16
16-bit integer command response
Unsigned16
32-bit integer command response
Unsigned32
Floating-point command argument
Float32
Length-of-Command/Response string
Unsigned32
64-character command response string
64-byte OctetString
Flag Indicating When to Command ACK
Bit Position for Cyclic Input
Data
Function
Bit 0
Command Channel Command
Acceptance Acknowledgement
Bit 15
Command Execution Error
PLC Output Data Name
Output Data Type
Not applicable
Not applicable
iVu Plus TG and Color Gen2 Image Sensors
182