Screen measurement 20
Screen measurement
The easiest way to do the screen measurement is by having the BeoSystem 4 within 1.8 m/6 ft distance from the BeoVision 12-65 if at all possible.
If this is not possible, see “Distance between BeoSystem 4 and BeoVision 12-65” below.
Screen measurement - introduction
The BeoSystem 4 requires some measurements to be made to match it to the BeoVision display it is connected to. These measurements consist of
two measurement sequences:
-
MEASURE SCREEN
: a measurement of the colour reproduction of the BeoVision display.
-
MEASURE LIGHT SENSOR
: a measurement of the ambient light sensor of the BeoVision display.
Prerequisite
The measurement involves the use of a reference
measurement device
, taken into use during installation by the installer. The reference
measurement device is part of the Calibration kit BeoSystem 4; Bang & Olufsen Part No. 3376493.
If the screen measurement is not made, the following text will be shown each time the television is switched
On
:
SCREEN NOT MEASURED
PLEASE CONTACT YOUR INSTALLER
Distance between BeoSystem 4 and BeoVision 12-65
Due to the length of the cable of the
measurement device
the distance between the BeoVision 12-65 and the BeoSystem 4 must be no more than
1.8 m/6 ft.
If the distance is longer, a USB extension cable must be used so that the measurement device can be connected to the USB socket of the
BeoSystem 4.
When USB extension cables longer than 5 m/16 ft are needed, they must be USB Active Extension Cables.
Initiating the Screen Measurement
Automatically
- Insert the USB plug of the measurement device into the USB socket of the BeoSystem 4. The screen measurement function is then presented
automatically.
The following text is shown as acknowledgement:
MEASUREMENT DEVICE DETECTED
, and one of the following two actions can
be chosen followed by pressing the
Centre
button:
-
DO NOTHING
: the system reverts to presenting the selected source.
-
PERFORM MEASUREMENT
: see Screen measurement
page 21
.
Via Customer Service Menu
In case the screen measurement menu does not show automatically or the measurement is to be initiated manually do the following to get to the
screen measurement menu. It is a prerequisite that the USB plug of the measurement device is inserted into the USB socket of the BeoSystem 4.
- On the remote control press
MENU
>
SETUP
and press the
Red
button and within 3 seconds press the
Centre
button.
- Select
PICTURE ADJUSTMENT
>
SCREEN MEASUREMENT.
- Select
SCREEN MEASUREMENT
and press the
Centre
button.