Standards and certifications • Requirements for immunity to disturbances (immunity)
Sect
ion 5
Sta
nda
rds a
nd
certi
fica
tion
s
279
Panel PC 800 User's Manual V 1.00
4.5 Conducted disturbances
4.6 Magnetic fields with electrical frequencies
4.7 Voltage dips, fluctuations and short-term interruptions
Test carried out according to
EN 61000-4-6
Limits according to
EN 61000-6-2
Limits according to
EN 61131-2
AC power I/O
150 kHz - 80 MHz, 10 V, 80%
amplitude modulation with 1 kHz,
length 3 seconds, criteria A
150 kHz - 80 MHz, 3 V, 80%
amplitude modulation with 1 kHz,
length 3 seconds, criteria A
DC power I/O
150 kHz - 80 MHz, 10 V, 80%
amplitude modulation with 1 kHz,
length 3 seconds, criteria A
150 kHz - 80 MHz, 3 V, 80%
amplitude modulation with 1 kHz,
length 3 seconds, criteria A
Functional ground connections
150 kHz - 80 MHz, 10 V, 80%
amplitude modulation with 1 kHz,
length 3 seconds, criteria A
150 kHz - 80 MHz, 3 V, 80%
amplitude modulation with 1 kHz,
length 3 seconds, criteria A
Signal connections >3 m
150 kHz - 80 MHz, 10 V, 80%
amplitude modulation with 1 kHz,
length 3 seconds, criteria A
150 kHz - 80 MHz, 3 V, 80%
amplitude modulation with 1 kHz,
length 3 seconds, criteria A
Table 161: Test requirements - Conducted disturbances
Test carried out according to
EN 61000-4-8
Limits according to
EN 61000-6-2
Limits according to
EN 61131-2
Test direction x, test in the field of
an induction coil 1 m x 1 m
30 A/m, criteria A
30 A/m, criteria A
Test direction y, test in the field of
an induction coil 1 m x 1 m
30 A/m, criteria A
30 A/m, criteria A
Test direction z, test in the field of
an induction coil 1 m x 1 m
30 A/m, criteria A
30 A/m, criteria A
Table 162: Test requirements - Magnetic fields with electrical frequencies
Test carried out according to
EN 61000-4-11
Limits according to
EN 61000-6-2
Limits according to
EN 61131-2
AC power inputs
Voltage dip
70% (30% reduction), 0.5 periods,
criteria B
-
AC power inputs
Voltage dip
40% (60% reduction), 5 periods,
criteria C
-
AC power inputs
Voltage dip
40% (60% reduction), 50 periods,
criteria C
-
AC power inputs
Voltage interruptions
< 5% (> 95% reduction), 250
periods, criteria C
-
AC power inputs
-
20 interruptions, 0.5 periods,
criteria A
Table 163: Test requirements - Voltage dips, fluctuations, and short-term interruptions
Summary of Contents for MAPPC800-ENG
Page 2: ...2 Panel PC 800 User s Manual V 1 00...
Page 4: ...4 Panel PC 800 User s Manual V 1 00...
Page 6: ...6 Panel PC 800 User s Manual V 1 00...
Page 16: ...16 Panel PC 800 User s Manual V 1 00 Table of contents...
Page 32: ...32 General information Model numbers Panel PC 800 User s Manual V 1 00...
Page 350: ...350 Accessories Cables Panel PC 800 User s Manual V 1 00...
Page 378: ...378 Appendix A Glossary Panel PC 800 User s Manual V 1 00...
Page 388: ...Table index 388 Panel PC 800 User s Manual V 1 00...