Technical data • Individual components

Panel PC 800 User's Manual V 1.00

Features

5AC801.DVRS-00

Data buffer capacity

2 MB

Noise level (complete read access)

Approx. 45 dBA at 50 cm

Lifespan

Opening/closing the drawer

60,000 POH (Power-On Hours)

> 10,000 times

Mechanical characteristics

Outer dimensions

Height
Width
Depth

172.5 mm

22 mm

150 mm

Weight

400 g

Environmental characteristics

Ambient temperature

2) 

Operation
Bearings
Transport

+5 to +55°C

3) 

-20 to +60°C
-40 to +65°C

Relative humidity

Operation
Bearings
Transport

8 to 80%, non-condensing
5 to 95%, non-condensing
5 to 95%, non-condensing

Vibration

Operation
Bearings
Transport

At max. 5 - 500 Hz and 0.2 g

At max. 5 - 500 Hz and 2 g
At max. 5 - 500 Hz and 2 g

Shock (pulse with a sine half-wave)

Operation
Bearings

Transport

At max. 5 g for 11 ms

At max. 60 g for 11 ms
At max. 200 g for 2 ms
At max. 60 g for 11 ms
At max. 200 g for 2 ms

1) RAM drivers are not provided by the manufacturer. Support of RAM function by the burning software "Nero" (model number

5SWUTI.0000-00) or other burning software packages and drivers from third party providers.

2) Temperature data is for operation at 500 meters. Derating the max. ambient temperature - typically 1°C per 1000 meters (from 500

meters above sea level).

3) Drive surface temperature

Table 62: Technical data - Slide-in DVD-R/RW, DVD+R/RW - 5AC801.DVRS-00

Summary of Contents for MAPPC800-ENG

Page 1: ...date of publication however Bernecker Rainer Industrie Elektronik Ges m b H makes no warranty expressed or implied with regards to the products or the documentation contained within this book In addi...

Page 2: ...2 Panel PC 800 User s Manual V 1 00...

Page 3: ...3 Panel PC 800 User s Manual V 1 00 Chapter 1 General information Chapter 2 Technical data Chapter 3 Commissioning Chapter 4 Software Chapter 5 Standards and certifications Chapter 6 Accessories...

Page 4: ...4 Panel PC 800 User s Manual V 1 00...

Page 5: ...5 Panel PC 800 User s Manual V 1 00 Figure index Table index Model number index Index Appendix A Chapter 7 Maintenance Servicing...

Page 6: ...6 Panel PC 800 User s Manual V 1 00...

Page 7: ...disposal 22 2 7 1 Separation of materials 22 3 Organization of safety notices 23 4 Directives 23 5 Model numbers 24 5 1 System units 24 5 2 CPU boards 945GME COM Express 24 5 3 Heat sink 25 5 4 Main m...

Page 8: ...I 50 2 6 3 Serial interface COM1 51 2 6 4 Ethernet 1 ETH1 52 2 6 5 Ethernet 2 ETH2 53 2 6 6 USB interfaces USB1 2 3 4 54 2 6 7 MIC Line IN Line OUT 56 2 6 8 Add on UPS slot 57 2 6 9 Status LEDs 58 2 6...

Page 9: ...1 card slot 5AC803 FA01 00 124 3 10 2 Fan kit 2 card slot 5AC803 FA02 00 125 3 10 3 Fan kit 3 card slot 5AC803 FA03 00 126 Chapter 3 Commissioning 127 1 Installation 127 1 1 Important mounting informa...

Page 10: ...ly on the PPC800 152 6 2 Remote connection to Automation Panel 900 via DVI 153 6 3 Remote connection to Automation Panel 800 900 via SDL 154 7 Configuration of a SATA RAID array 155 7 1 Create RAID se...

Page 11: ...2 Advanced 219 1 9 3 Boot 226 1 9 4 Security 227 1 9 5 Power 227 1 10 BIOS Error signals beep codes 228 1 10 1 BIOS 945GME 228 1 11 Distribution of resources 229 1 11 1 RAM address assignment 229 1 1...

Page 12: ...ion Device Interface ADI Control Center 257 8 1 Function 257 8 2 Installation 259 8 3 SDL equalizer setting 260 8 4 UPS configuration 261 8 4 1 Installing the UPS service for the B R APC add on UPS 26...

Page 13: ...tuations in operation 285 6 6 Humid heat cyclic 285 6 7 Humid heat constant storage 285 7 Safety 286 7 1 Ground resistance 286 7 2 Insulation resistance 287 7 3 High voltage 287 7 4 Residual voltage 2...

Page 14: ...n and storage 319 9 4 Dimensions 319 10 USB flash drive 320 10 1 General information 320 10 2 Order data 320 10 3 Technical data 320 10 3 1 Temperature humidity diagram Operation and storage 322 11 B...

Page 15: ...cations 345 13 6 RS232 cable 346 13 6 1 Order data 346 13 6 2 Technical data 346 13 6 3 Cable specifications 347 13 7 USB cable 348 13 7 1 Order data 348 13 7 2 Technical data 348 13 7 3 Cable specifi...

Page 16: ...16 Panel PC 800 User s Manual V 1 00 Table of contents...

Page 17: ...l history Information B R does its best to keep the printed versions of its user s manuals as current as possible However any newer versions of the User s Manual can always be downloaded in electronic...

Page 18: ...updated Section 6 Panel PC 800 with Windows Embedded Standard 2009 on page 253 updated Section 4 Connection examples on page 135 updated Chapter 5 Standards and certifications on page 271 updated The...

Page 19: ...the control of weapons systems 2 2 Protection against electrostatic discharges Electrical components that are vulnerable to electrostatic discharge ESD must be handled accordingly 2 2 1 Packaging Ele...

Page 20: ...trollers and when using operating and monitoring devices as control systems in conjunction with a soft PLC e g B R Automation Runtime or comparable products or a slot PLC e g B R LS251 or comparable p...

Page 21: ...ed when testing the operating and monitoring devices or the uninterruptible power supply even when operating them for only a short time Before turning the device on make sure that all parts with volta...

Page 22: ...onmentally friendly disposal All B R programmable controllers operating and monitoring devices and uninterruptible power supplies are designed to inflict as little harm on the environment as possible...

Page 23: ...all dimensions e g dimension diagrams etc Safety notice Description Danger Disregarding the safety regulations and guidelines can be life threatening Caution Disregarding the safety regulations and gu...

Page 24: ...ule See page 78 5PC800 B945 10 CPU board Intel Core Duo L2400 1 66 GHz 2 667 MHz FSB 2 MB L2 cache 945GME chipset 2 sockets for SO DIMM DDR2 module See page 78 5PC800 B945 01 CPU board Intel Core 2 Du...

Page 25: ...1024 01 SO DIMM DDR2 1024MB PC2 5300 See page 80 5MMDDR 2048 01 SO DIMM DDR2 2048MB PC2 5300 See page 80 Table 7 Model numbers Main memory Model number Short description Note 5AC803 SX01 00 PPC800 Exp...

Page 26: ...g compact slide in drives in a slide in slot drive slot See page 105 5AC801 HDDI 00 APC810 slide in compact HDD 40GB 40 GB SATA hard disk slide in compact 24 7 hard disk with extended temperature rang...

Page 27: ...Model numbers Batteries Model number Short description Note 0TB103 9 Plug 24V 5 08 3 pin screw clamps 24 VDC 3 pin connector female Screw clamp 3 31 mm protected against vibration by the screw flange...

Page 28: ...B R CompactFlash card with 4096 MB SLC NAND flash and IDE ATA interface See page 311 5CFCRD 8192 04 CompactFlash 8192 MB B R CompactFlash card with 8192 MB SLC NAND flash and IDE ATA interface See pag...

Page 29: ...m See page 330 5CASDL 0050 01 SDL cable 5 m 45 SDL cable for fixed type of layout with one sided 45 plug length 5 m See page 333 5CASDL 0050 03 5 m flex SDL cable SDL cable for fixed and flexible type...

Page 30: ...able DB9 f DB9 m 1 8 m RS232 extension cable for remote operation of a display unit with touch screen length 1 8 m See page 346 9A0014 05 RS232 cable DB9 f DB9 m 5 m RS232 extension cable for remote o...

Page 31: ...ws XP Professional Service Pack 3 CD multi language Only available with a new device See page 249 5SWWXP 0500 GER WinXP Professional with SP 2c GER Microsoft OEM Windows XP Professional Service Pack 2...

Page 32: ...32 General information Model numbers Panel PC 800 User s Manual V 1 00...

Page 33: ...uch screen displays provide a simple and intuitive user interface The flexibility was raised to a new level when designing the PPC800 Therefore many options can be implemented on the cost optimized ba...

Page 34: ...able expansion with 1 or 2 slots for PCI PCI Express PCIe cards and a slide in drive slot 1 optional PCIec PCI express compact card slot can be expanded with option 1 optional slide in compact slot ca...

Page 35: ...ory such as CompactFlash card or hard disk for the operating system Software 1 2 1 Configuration Basic system Figure 1 Configuration Basic system 5AC803 HS00 02 5PC800 B945 05 CPU board 5AC803 HS00 01...

Page 36: ...ction cable Battery 5CAUPS 0005 00 0 5 meter or 5CAUPS 0030 00 3 meters APC c 5CFCRD 0064 03 5CFCRD 0128 03 5CFCRD 0256 03 5CFCRD 0512 03 5CFCRD 1024 03 5CFCRD 2048 03 5CFCRD 4096 03 5CFCRD 8192 03 5A...

Page 37: ...rnIn testing tool BurnIn V4 0 Pro from Passmark Software to simulate a 100 load on the interface via loop back adapters serial interfaces slide in drives USB interfaces audio outputs Maximum system ex...

Page 38: ...HDDS 00 Additional insert cards PCIec card slot Board power Slide in drive Power Supply All temperature values in degrees celsius C at 500 meters above sea level Derating of the maximum ambient temper...

Page 39: ...th the heat sink 5AC803 HS00 01 Rev A5 If a heat sink with an earlier revision is used then the maximum ambient temperature of the CPU board 5PC800 B954 04 must be referred to 2 Only possible with a C...

Page 40: ...800 The position of the temperature sensors can be found in the figure Temperature sensor locations on page 353 The value listed in the table represents the defined maximum temperature for this measur...

Page 41: ...es can be found in the technical data for the individual components Component Operation Storage Transport CPU boards 945GME COM Express 10 90 5 95 Main memory for CPU boards 10 90 5 95 Slide in compac...

Page 42: ...ed on e g using the power button the voltages 3V3 and 5 V are placed on the bus At the 5 V output another DC DC converter generates 12 V and places these on the bus An additional DC DC converter gener...

Page 43: ...C800 B945 11 5PC800 B945 02 5PC800 B945 12 1 The total performance of one PCI PCIe card per PCI slot sum of power consumptions for each voltage area may not exceed the limits stated for operation with...

Page 44: ...rformance of one PCI PCIe card per PCI slot sum of power consumptions for each voltage area may not exceed the limits stated for operation with or without a fan kit Information All values in watts gen...

Page 45: ...switching ADC DC DC switching DC DC switching 5V 3 3V 12V 15 6V USB0 5V USB2 USB4 Gbit LAN1 PCIe 0 PCIe 1 4 I2C module LPC bus USB 6 I2C Power control Power good USB7 SM bus USB5 PCIe SATA 1 COM 1 SD...

Page 46: ...ed a unique serial number label with a bar code type 128 which allows the device to be clearly identified This serial number represents all of the components built into the system model number name re...

Page 47: ...e serial number of the entire device found behind the front door in the serial number search field on the start page www br automation com The search provides you with a detailed list of the individua...

Page 48: ...tage is protected internally by a soldered fuse 15A fast acting so that the device cannot be damaged if there is an overload fuse replacement necessary or if the voltage supply is connected incorrectl...

Page 49: ...fasten a copper strip that is built into the PPC800 at a central grounding point in the switching cabinet or system The largest possible conductor cross section should be used at least 2 5 mm Caution...

Page 50: ...output For details see technical data for the CPU board being used CPU board Video signals with all system unit variations 5PC800 B945 00 RGB DVI SDL 5PC800 B945 01 RGB DVI SDL 5PC800 B945 02 RGB DVI...

Page 51: ...e were numbered accordingly for easy identification This numbering can differ from the numbering used by the particular operating system Type RS232 modem capable not electrically isolated 9 pin DSUB m...

Page 52: ...erating system Controller Realtek RTL8111B C2 2 The Realtek RTL8111C is integrated in the CPU boards 5PC800 B945 05 5PC800 B945 10 5PC800 B945 11 5PC800 B945 12 5PC800 B945 13 5PC800 B945 14 RJ45 twis...

Page 53: ...dentification This numbering can differ from the numbering used by the particular operating system Controller Intel 82574 RJ45 twisted pair 10BaseT 100BaseT female Cabling S STP Cat5e Transfer rate 10...

Page 54: ...PC specifications this interface should be handled with extreme care with regard to EMC location of cables etc Universal Serial Bus USB1 USB2 USB3 USB4 1 1 The interfaces etc available on the device o...

Page 55: ...sy identification This numbering can differ from the numbering used by the particular operating system Transfer rate Low speed 1 5 MBit s full speed 12 MBit s to high speed 480 MBit s 1 x USB type A f...

Page 56: ...ecessary software can be downloaded from the download area on the B R homepage www br automation com MIC Line IN Line OUT Controller Realtek ALC 662 3 5 mm jack female MIC Connection of a mono microph...

Page 57: ...ories section 6 Uninterruptible power supply on page 300 Add on UPS slot Add on UPS accessories 5AC600 UPSI 00 Add on UPS module 5AC600 UPSB 00 Battery unit 5 Ah 5CAUPS 0005 00 UPS cable 0 5 m 5CAUPS...

Page 58: ...ed green Blinking MTCX upgrade service function A red green blinking power LED indicates a faulty or incomplete MTCX upgrade The MTCX runs using the firmware version installed when delivered This coul...

Page 59: ...CMOS profile switch Switch position Description 0 Profile 0 Default profile reserved 1 Profile 1 Optimized for system units 5PC810 SX01 00 and 5PC810 SX02 00 2 Profile 2 Optimized for 5PC810 SX05 00...

Page 60: ...PPC800 or shuts down operating system and switches off the PPC800 Press and hold ATX power supply switches off without shutting down the PPC800 data could be lost Pressing the power button does not re...

Page 61: ...e measurement and then evaluated The evaluated battery status is displayed in the BIOS Setup pages under Advanced Main board monitor and in the B R Control Center ADI driver but can also be read in a...

Page 62: ...Flash card 5CFCRD 2048 04 2048 MB B R CompactFlash card 5CFCRD 4096 04 4096 MB B R CompactFlash card 5CFCRD 8192 04 8192 MB B R CompactFlash card 5CFCRD 016G 04 16 GB B R CompactFlash card 5CFCRD 0064...

Page 63: ...B R CompactFlash card 5CFCRD 2048 04 2048 MB B R CompactFlash card 5CFCRD 4096 04 4096 MB B R CompactFlash card 5CFCRD 8192 04 8192 MB B R CompactFlash card 5CFCRD 016G 04 16 GB B R CompactFlash card...

Page 64: ...HDDI 00 APC810 and PPC800 slide in compact HDD 40GB EE25 5AC801 HDDI 02 APC810 and PPC800 slide in compact HDD 160GB EE25 5AC801 SSDI 00 APC810 and PPC800 slide in compact SSD 32GB SLC Table 41 Slide...

Page 65: ...PCI Express compact 5ACPCC ETH0 00 PCIec Ethernet card 10 100 1000 PCIec Ethernet plug in card 1 Ethernet interface 10 100 1000 5ACPCC MPL0 00 PCIec POWERLINK MN 2 port PCIec POWERLINK plug in card 2...

Page 66: ...5 00 PANEL PC O pen Close USB connection on front PCIec Card slot Add on UPS slot USB 1 USB2 USB3 USB4 Ethernet 2 10 100 1000 ETH2 HDA Sound MIC Line IN Line OUT Reset button COM1 RS232 Supply voltage...

Page 67: ...n Yes Power button Yes Buzzer Yes LED Amount 4 directed outwards via fiber optic lines Controller Bootloader BIOS Processor Cooling Method Component dependent see technical data for the 3 2 CPU boards...

Page 68: ...s Amount 1 or 2 optional PCIec slots Amount 1 optional with 5AC803 BC01 00 Insert for slide in compact drive Amount 1 optional with 5AC803 BC02 00 Insert for slide in drive 1 Amount Component dependen...

Page 69: ...pth See also Dimensions on page 70 435 mm 330 mm Component dependent Weight Approx 5 5 kg component dependent Environmental characteristics Ambient temperature Operation Storage Transport See 2 1 1 Ma...

Page 70: ...f the half brightness time Figure 14 Dimensions 5PC820 1505 00 up to 6 mm over 6 to 30 mm over 30 to 120 mm over 120 to 400 over 400 to 1000 0 1 mm 0 2 mm 0 3 mm 0 5 mm 0 8 mm Nominal General toleranc...

Page 71: ...anel PC 800 with preassembled mounting blocks is installed e g in a housing cutout A cutout that corresponds to the following drawing must be made Figure 15 Cutout installation 5PC820 1505 00 0 Cut ou...

Page 72: ...f the mounting screws which can be determined by a broken seal voids all warranty During operation surface temperatures of the heat sink may reach 70 C warning hot surface PANEL PC O pen Close USB con...

Page 73: ...78 Power failure logic Controller Buffer time MTCX1 10 ms Battery Type Removable Lifespan Renata 950 mA Yes accessible from the outside 2 years Interfaces Serial interfaces Type Amount UART Transfer r...

Page 74: ...uch Analog resistive Elo serial 12 bit 81 3 Display Type Diagonal Colors Resolution Contrast Viewing angle see page 361 Horizontal Vertical Background lighting Brightness Half brightness time3 Color T...

Page 75: ...5 and 50 C max 80 non condensing 40 C 5 to 90 and 40 C 90 non condensing 40 C 5 to 90 and 40 C 90 non condensing Vibration Operation continuous Operation occasional Storage Transport 2 9 Hz 1 75 mm 9...

Page 76: ...1000 0 1 mm 0 2 mm 0 3 mm 0 5 mm 0 8 mm Nominal General tolerance acc measurement range to DIN ISO 2768 medium 311 475 76 527 26 421 222 369 A 5 7 26 Information The value depends on the expansion be...

Page 77: ...l PC 800 with preassembled mounting blocks is installed e g in a housing cutout A cutout that corresponds to the following drawing must be made Figure 19 Cutout installation 5PC820 1906 00 Cut out dim...

Page 78: ...06 GHz 65 nm 32 KB 2 MB 533 MHz Intel Celeron M 423 1 06 GHz 65 nm 32 KB 1 MB 533 MHz Intel Core 2 Duo T7400 2 16 GHz 65 nm 32 KB 4 MB 667 MHz Intel Atom N270 1 66 GHz 45 nm 24 KB 512 kB 533 MHz Chip...

Page 79: ...HS00 00 5AC803 HS00 01 5AC803 HS00 02 Ideal for CPU boards 5PC800 B945 00 5PC800 B945 01 5PC800 B945 02 5PC800 B945 03 5PC800 B945 10 5PC800 B945 11 5PC800 B945 12 5PC800 B945 13 5PC800 B945 04 5PC80...

Page 80: ...hen two modules of different sizes e g 1 GB and 2 GB are plugged in When two 2 GB modules are plugged in only 3 GB of main memory can be used 3 4 1 Technical data Figure 22 Main memory Features 5MMDDR...

Page 81: ...sion The PPC800 expansion is an expandable extension for mounting up to 2 PCI PCIe cards and a slide in drive Figure 23 1 slot and 2 slot expansion Figure 24 Expansion description 1 slot expansion 2 s...

Page 82: ...ount 1 1 Mechanical characteristics Dimensions Width Height Depth 167mm 222 mm 60 mm 167mm 222 mm 80 mm Weight Approx 1 kg Approx 1kg Table 48 Technical data Expansion Figure 25 Dimensions Expansion 5...

Page 83: ...Manual V 1 00 3 5 3 Dimensions 5PC803 SX02 00 Figure 26 Dimensions Expansion 5PC803 SX02 00 0 1 mm 0 2 mm 0 3 mm 0 5 mm 0 8 mm General tolerance acc to DIN ISO 2768 medium up to 6 mm over 6 to 30 mm o...

Page 84: ...Express PCIe half size cards can be plugged in depending on the type of bus unit They cannot exceed the following dimensions Figure 27 Dimensions Standard half size PCI card Figure 28 Dimensions Stand...

Page 85: ...essories Short description 5AC801 ADAS 00 APC810 and PPC800 slide in compact adapter 5AC801 HDDS 00 APC810 and PPC800 slide in HDD EE25 5AC801 DVRS 00 APC810 and PPC800 slide in DVD R RW 5AC801 DVDS 0...

Page 86: ...he bus units are compatible with the expansions in 1 or 2 PCI slot sizes available with PCI and or PCI Express support Figure 29 1 slot bus units Figure 30 2 slot bus units 5PC803 BX01 01 5PC803 BX01...

Page 87: ...1 Technical data Inserts 5AC803 BX01 00 5AC803 BX01 01 5AC803 BX02 00 5AC803 BX02 01 PCI slot Amount Default PCI bus type Bus speed 1 2 2 32 bit 33 MHz 2 2 2 32 bit 33 MHz 1 2 2 32 bit 33 MHz PCI Exp...

Page 88: ...the system unit If the option 5AC803 BC02 00 is selected then a slide in compact drive can be operated in the system unit It is also possible to select both options so that a PCIec plug in card and a...

Page 89: ...nd in the ADI Figure 32 Dimensions PCIec cards Information Only B R PCIec cards that were specially designed for the Automation PC 820 and Panel PC 800 can be used Information The option 5AC803 BC01 0...

Page 90: ...ure 33 Ethernet card 10 100 1000 5ACPCC ETH0 00 Information The following characteristics features and limit values only apply to this individual component and can deviate from those specified for the...

Page 91: ...te 10 100 1000 MBit s1 1 Change over takes place automatically Cable length max 100 m min Cat5e Speed LED On Off Green 100 Mbit s 10 Mbit s2 2 The 10 MBit s transfer speed connection is only present i...

Page 92: ...ied for the entire device For the entire device in which this individual component is used refer to the data given specifically for the entire device POWERLINK card 2 connections Cabling S STP Cat5e T...

Page 93: ...status the interface goes into the PRE_OPERATIONAL_1 state single flash Single flash approx 1 Hz PRE_OPERATIONAL_1 The interface status is PRE_OPERATIONAL_1 Managing Node MN The MN starts the operati...

Page 94: ...ber x1 x16 Both of these hex switches x16 x1 are used to configure the station number for the POWERLINK Station numbers are permitted between 00 and FD Switch position x1 x16 Description 0 0 Operation...

Page 95: ...pact drives Figure 36 Slide in compact HDD 40GB EE25 5AC801 HDDI 00 Information The following characteristics features and limit values only apply to this individual component and can deviate from tho...

Page 96: ...40 to 95 C Relative humidity3 Operation Bearings Transport 5 to 90 non condensing 5 to 95 non condensing 5 to 95 non condensing Vibration Operation Bearings 2 g at 5 500 Hz no non recovered errors 5 g...

Page 97: ...emperature specification must be reduced linearly by 1 C every 305 meters The temperature increase and decrease can be a maximum of 20 C per hour Figure 37 Temperature humidity diagram 5AC801 HDDI 00...

Page 98: ...HDD 160 GB 5AC801 HDDI 02 Information The following characteristics features and limit values only apply to this individual component and can deviate from those specified for the entire device For th...

Page 99: ...o 80 C 40 to 95 C 40 to 95 C Relative humidity3 Operation Bearings Transport 8 to 90 non condensing maximum humidity at 29 C 5 to 95 non condensing maximum humidity at 40 C 5 to 95 non condensing maxi...

Page 100: ...pecification must be reduced linearly by 1 C every 305 meters The temperature increase and decrease can be a maximum of 20 C per hour Figure 39 Temperature humidity diagram 5AC801 HDDI 02 Temperature...

Page 101: ...DI 00 Caution A sudden loss of power can cause data to be lost In very rare cases the mass memory may also become damaged To prevent damage and loss of data it is recommended to use a UPS device Infor...

Page 102: ...Flash Yes Wear leveling Static Error Correction Coding ECC Yes Compatibility SATA revision 2 6 compliant compatible with SATA 1 5 Gbit s and 3 Gbit s interface rates ATA ATAPI 7 SSD Enhanced SMART ATA...

Page 103: ...ms Altitude Operation Bearings Transport 300 to 12 192 m 300 to 12 192 m 300 to 12 192 m 1 IOPS Random read and write input output operations per second Figure 41 Temperature humidity diagram 5AC801...

Page 104: ...or cyclic reading and writing Figure 42 ATTO disk benchmark v2 34 cyclic read Figure 43 ATTO disk benchmark v2 34 cyclic write 0 5 1 2 4 8 16 32 128 64 256 512 1024 2048 4096 8192 Transfer rate MB s T...

Page 105: ...00 Technical data Information The expansion 5AC803 SX01 00 or 5AC803 SX02 00 is required in order to use slide in drives Figure 44 Hard disk adapter slide in compact 5AC801 ADAS 00 Mechanical characte...

Page 106: ...owing characteristics features and limit values only apply to this individual component and can deviate from those specified for the entire device For the entire device in which this individual compon...

Page 107: ...5 C 40 to 95 C Relative humidity3 Operation Bearings Transport 5 to 90 non condensing 5 to 95 non condensing 5 to 95 non condensing Vibration Operation Bearings 2 g at 5 500 Hz no non recovered errors...

Page 108: ...pecification must be reduced linearly by 1 C every 305 meters The temperature increase and decrease can be a maximum of 20 C per hour Figure 46 Temperature humidity diagram 5AC801 HDDS 00 Temperature...

Page 109: ...D ROM 5AC801 DVDS 00 Information The following characteristics features and limit values only apply to this individual component and can deviate from those specified for the entire device For the enti...

Page 110: ...A in a distance of 50 cm Lifespan Opening closing the drawer 60 000 POH Power On Hours 10 000 times Mechanical characteristics Outer dimensions Height Width Depth 172 5 mm 22 mm 150 mm Weight 455 g En...

Page 111: ...from 500 meters above sea level Hot plug capable Hardware revision B0 of the slide in DVD ROM 5AC801 DVDS 00 does not offer SATA hot plug capability Other hardware revisions are hot plug capable Figu...

Page 112: ...components Panel PC 800 User s Manual V 1 00 3 9 7 Slide in DVD R RW 5AC801 DVRS 00 Information The expansion 5AC803 SX01 00 or 5AC803 SX02 00 is required in order to use slide in drives Figure 49 Sli...

Page 113: ...ax 33 3 MB s Access time average CD DVD 140 ms 24x 150 ms 8x Revolution speed Max 5160 rpm 1 Starting time 0 rpm to read access CD DVD 14 seconds maximum 15 seconds maximum Host interface SATA Readabl...

Page 114: ...g 5 to 95 non condensing Vibration Operation Bearings Transport At max 5 500 Hz and 0 2 g At max 5 500 Hz and 2 g At max 5 500 Hz and 2 g Shock pulse with a sine half wave Operation Bearings Transport...

Page 115: ...t 500 meters Derating the max ambient temperature typically 1 C per 1000 meters from 500 meters above sea level Figure 50 Temperature humidity diagram Slide in DVD R RW DVD R RW 5AC801 DVRS 00 0 0 10...

Page 116: ...le for 24 hour operation Only requires 1 PCI slot Transfer rates up to 150 MB s Figure 51 PCI SATA RAID controller 5ACPCI RAIC 03 Information The PCI SATA RAID controller can not be used in place of a...

Page 117: ...2 KB Hard disks Amount Fujitsu M120 ESW MHY2160BH ESW 2 Formatted capacity 512 bytes sector 160 GB Number of heads 3 Number of sectors user 312 581 808 Bytes per sector 512 Revolution speed 5400 rpm 1...

Page 118: ...0 5 octaves per minute no damage 5 500 Hz max 5 g duration 0 5 octaves per minute no damage Shock 4 pulse with a sine half wave Operation Bearings Max 125 g 2 ms no unrecoverable errors Max 400 g 2 ms...

Page 119: ...available for download on the B R Homepage in the download area www br automation com The NET based SATARaid serial ATA RAID management software can also be found on the B R homepage Configuration For...

Page 120: ...al V 1 00 Exchanging a HDD A hard drive can be easily exchanged in the event of an error when using the RAID1 mirroring configuration without having to re install the system The replacement SATA HDD 1...

Page 121: ...component is used refer to the data given specifically for the entire device Features 5ACPCI RAIC 04 Hard disks Amount Fujitsu M120 ESW MHY2160BH ESW 1 Formatted capacity 512 bytes sector 160 GB Numb...

Page 122: ...ors 5 500 Hz max 5 g duration 0 5 octaves per minute no damage 5 500 Hz max 5 g duration 0 5 octaves per minute no damage Shock 4 pulse with a sine half wave Operation Bearings Max 125 g 2 ms no unrec...

Page 123: ...humidity diagram Operation and storage Figure 54 Temperature humidity diagram SATA RAID hard disk 5ACPCI RAIC 04 Temperature C Relative humidity RH non condensing Operation Storage Transport 0 10 20...

Page 124: ...temperature limits e g DVD combos PCI cards etc The fan and dust filter are subject to wear and must be checked with appropriate frequency and cleaned or replaced when not functioning properly e g du...

Page 125: ...ng of the filter kit is appropriate at that time Figure 56 Fan kit 5AC803 FA02 00 Features 5AC803 FA02 00 Fan type Width Length Height 40 mm 40 mm 10 mm Revolution speed 6100 rpm Noise level 21 dB Lif...

Page 126: ...70 mm 15 mm Revolution speed 6100 rpm 4300 rpm 10 Noise level 21 dB 5 dB Lifespan 95 000 at 20 C 29 000 at 70 C 60 000 at 40 C Maintenance interval The fans are subject to wear Depending on the work e...

Page 127: ...ped In order to tighten or loosen the screws a hex key size 3 is required for the plastic clamps and a Torx screwdriver size 20 or a large flat head screwdriver for the aluminum die casting The maximu...

Page 128: ...surface The PPC800 is only for operation in closed rooms The PPC800 cannot be situated in direct sunlight The vent holes may not be covered When mounting the device be sure to adhere to the allowable...

Page 129: ...C800 system must be mounted as described in the following sections 1 2 1 Standard mounting In order to guarantee natural air circulation mount the system so that the spacing on the top bottom and side...

Page 130: ...2 Standard mounting with 5AC801 DVRS 00 In order to guarantee natural air circulation mount the system so that the spacing on the top bottom and sides is as indicated in section 1 2 4 Spacing for air...

Page 131: ...l V 1 00 1 2 3 Standard mounting with 5AC801 DVDS 00 In order to guarantee natural air circulation mount the system so that the spacing on the top bottom and sides is as indicated in section 1 2 4 Spa...

Page 132: ...ation allow the specified amount of space above below to the side and behind the Panel PC 800 The minimum specified free space can be found in the diagram below Figure 62 Distances for air circulation...

Page 133: ...1 00 2 Cable connections When making cable connections and installing cables it is not permitted to have a flex radius smaller than the minimum value specified Information The value specified for the...

Page 134: ...ion for persons The PPC800 functional ground has 2 connections Supply voltage Ground connection To guarantee secure dissipation of electric disturbances the following points should be observed The dev...

Page 135: ...900 devices can be connected per line How many Automation Panel 900 devices can be connected to an Automation Panel 800 device per line How are the connected devices internally numbered Are there lim...

Page 136: ...ons for the PPC800 system unit with CPU board to implement the configuration shown in the figure above If the maximum resolution is limited when making the combination then it is also shown in the fol...

Page 137: ...th 5CADVI 0018 00 DVI cable 1 8 m 5CADVI 0050 00 DVI cable 5 m 5CADVI 0100 00 DVI cable 10 m1 1 USB support is not possible on the Automation Panel 900 because USB is limited to 5 m 9A0014 02 Touch sc...

Page 138: ...00 4 2 5 BIOS settings No special BIOS settings are necessary for operation 1 USB support is not possible on the Automation Panel 900 because USB is limited to 5 m Information The DVI transfer mode do...

Page 139: ...ited when making the combination then it is also shown in the following table e g for connecting a non B R Automation Panel 900 device Figure 65 Configuration One Automation Panel 900 via SDL CPU boar...

Page 140: ...45 plug for fixed type of layout 10 m 5CASDL 0100 03 SDL cable for fixed and flexible type of layout 10 m 5CASDL 0150 00 SDL cable for a fixed type of layout 15 m 5CASDL 0150 01 SDL cable with 45 plu...

Page 141: ...DL 0050 01 5CASDL 0050 03 5CASDL 0050 00 5CASDL 0050 01 5CASDL 0050 03 5CASDL 0050 00 5CASDL 0050 01 5CASDL 0050 03 5CASDL 0050 00 5CASDL 0050 01 5CASDL 0050 03 5CASDL 0050 00 5CASDL 0050 01 5CASDL 00...

Page 142: ...g the combination then it is also shown in the following table e g for connecting a non B R Automation Panel 900 device Figure 66 Configuration One Automation Panel 800 via SDL CPU board with system u...

Page 143: ...ed and flexible type of layout 15 m 5CASDL 0200 20 SDL cable for fixed and flexible type of layout 20 m 5CASDL 0250 20 SDL cable for fixed and flexible type of layout 25 m 5CASDL 0300 30 SDL cable wit...

Page 144: ...ttings No special BIOS settings are necessary for operation Touch screen functionality The COM C must be enabled in BIOS in order to operate the connected panel touch screen on the monitor panel conne...

Page 145: ...ment the configuration shown in the figure above If the maximum resolution is limited when making the combination then it is also shown in the following table e g for connecting a non B R Automation P...

Page 146: ...panel touch screen on the monitor panel connection found in the BIOS menu under Advanced Main board Panel Features Legacy Devices Model number Description Note 5DLSDL 1000 01 Automation Panel Link SDL...

Page 147: ...C800 system unit with CPU board to implement the configuration shown in the figure above If the maximum resolution is limited when making the combination then it is also shown in the following table e...

Page 148: ...and flexible type of layout 1 8 m 5CASDL 0050 00 SDL cable for a fixed type of layout 5 m 5CASDL 0050 01 SDL cable with 45 plug for fixed type of layout 5 m 5CASDL 0050 03 SDL cable for fixed and flex...

Page 149: ...L 0018 03 5 5CASDL 0050 00 5CASDL 0050 01 5CASDL 0050 03 5CASDL 0050 00 5CASDL 0050 01 5CASDL 0050 03 5CASDL 0050 00 5CASDL 0050 01 5CASDL 0050 03 5CASDL 0050 00 5CASDL 0050 01 5CASDL 0050 03 5CASDL 0...

Page 150: ...ttings No special BIOS settings are necessary for operation Touch screen functionality The COM C must be enabled in BIOS in order to operate the connected panel touch screen on the monitor panel conne...

Page 151: ...B R homepage www br automation com The touch screen should be calibrated while installing the driver 5 2 Windows CE Windows CE starts the touch screen calibration sequence during its first boot in th...

Page 152: ...fer rate is USB 2 0 Warning Peripheral USB devices can be connected to the USB interfaces Due to the vast number of USB devices available on the market B R cannot guarantee their performance B R does...

Page 153: ...erfaces on the Automation Panel 900 These can each handle a load of 500 mA The maximum transfer rate is USB 2 0 Information Only end devices no hubs can be connected to the Automation Panel 900 Figure...

Page 154: ...USB connections on the Automation Panel 800 devices These can each handle a load of 500 mA The maximum transfer rate is USB 1 1 Information Only end devices no hubs can be connected to the Automation...

Page 155: ...ers 5ACPCI RAIC 01 and 5ACPCI RAIC 03 Figure 72 Open the RAID Configuration Utility Figure 73 RAID Configuration Utility Menu SiI 3512A SATARaid BIOS Verison 4 3 79 Copyright C 1997 2006 Silicon Image...

Page 156: ...the next item Enter Select an item or open a submenu ESC Go back to previous menu Ctrl E Exit setup and save the changed settings Table 86 BIOS relevant keys in the RAID Configuration Utility Figure 7...

Page 157: ...second HDD as well as the Chunk Size block size application dependent Figure 75 RAID Configuration Utility Create RAID set Striped RAID Configuration Utility Silicon Image Inc Copyright C 2006 Press E...

Page 158: ...ether a rebuild mirror should be performed immediately approx 50 minutes Figure 76 RAID Configuration Utility Create RAID set Mirrored RAID Configuration Utility Silicon Image Inc Copyright C 2006 Pre...

Page 159: ...Figure 77 RAID Configuration Utility Delete RAID set RAID Configuration Utility Silicon Image Inc Copyright C 2006 Create RAID set Rebuild Mirrored set Resolve Conflicts Low Level Format 0 PM 1 SM 0...

Page 160: ...program SATARaid detected a new event and the rebuild is started The entire rebuild lasts approximately 50 minutes If offlinerebuild is selected then a rebuild is performed immediately before starting...

Page 161: ...status of the hard disk is conflict Figure 79 RAID Configuration Utility Resolve conflicts RAID Configuration Utility Silicon Image Inc Copyright C 2006 Create RAID set Delete RAID set Help for resolv...

Page 162: ...not configured A low level format of a hard disk takes approx 40 minutes Figure 80 RAID Configuration Utility Low level format RAID Configuration Utility Silicon Image Inc Copyright C 2006 Create RAID...

Page 163: ...This behavior occurs near the limits of the time frame provided for startup The problem described above can occur because the startup time for the CompactFlash cards fluctuates due to the variance of...

Page 164: ...oximate 50 increase of the half brightness time 9 2 Image sticking Image sticking is the burning in of a static image on a display after being displayed for a prolonged period of time However this doe...

Page 165: ...User s Manual V 1 00 9 2 2 How can image sticking be avoided continual change between static and dynamic images avoiding excessive brightness contrast between foreground and background display use of...

Page 166: ...166 Commissioning User tips for increasing the display lifespan Panel PC 800 User s Manual V 1 00...

Page 167: ...red to the CMOS If the data is not OK then the CMOS data is checked for validity An error message is output if the CMOS data contains errors and the boot procedure can be continued by pressing the F1...

Page 168: ...at POST AMIBIOS C 2003 American Megatrends Inc APC2R115 Bernecker Rainer Industrie Elektronik H1 15 Serial Number 133453 CPU Intel R Core TM 2 CPU T7400 2 16GHz Speed 2 16 Ghz Press DEL to run Setup P...

Page 169: ...us item Cursor Go to the next item Changes the setting of the selected function Enter Changes to the selected menu PageUp Change to the previous page PageDown Change to the previous page Pos 1 Jumps t...

Page 170: ...cy Displays the processor frequency None System Memory Displays the system memory size None Product Revision Displays the CPU board HW revision None Serial Number Displays the CPU board serial number...

Page 171: ...tion Configures the graphics settings Enter Opens the submenu See Graphics configuration on page 181 CPU configuration Configures the CPU settings Enter Opens the submenu See CPU configuration on page...

Page 172: ...USB settings Enter Opens the submenu See USB configuration on page 198 Keyboard mouse configuration Configures the keyboard mouse options Enter Opens the submenu See Keyboard mouse configuration on p...

Page 173: ...spend mode Selects the ACPI status to be used when Suspend Mode is enabled S1 POS Sets S1 as Suspend mode Only a few functions are disabled and are available again at the touch of a button S3 STR Sets...

Page 174: ...h this function a temperature can be set at which the CPU automatically reduces its speed Disabled Disables this function 50 C 60 C 70 C 80 C 90 C Temperature setting for the passive cooling trip poin...

Page 175: ...ment of a PCI interrupt No No assignment of an interrupt Allocate IRQ to PCIEX2 Use this function to set whether or not the PCIEX2 is assigned a PCI interrupt Yes Automatic assignment of a PCI interru...

Page 176: ...93 945GME Advanced PCI IRQ Resource Exclusion Setting options Advanced PCI IRQ Resource Exclusion Available Specified IRQ is available to be used by PCI PnP devices Reserved Specified devices IRQ5 Ava...

Page 177: ...E INTD UHCI3 PATA Option for setting the PIRQ E Auto Automatic assignment by the BIOS and operating system 5 6 7 9 10 11 12 Manual assignment Table 94 945GME Advanced PCI Interrupt Routing Setting opt...

Page 178: ...ely no IRQ sharing Information Is only displayed if a PIRQ is manually set e g 5 None No interrupt is assigned x Assigns the PIRQ as 1st exclusive PCI IRQ 2nd Exclusive PCI With this option you can de...

Page 179: ...eactivates the PCI Express connection function Information If you are not using any PCI Express devices this option should be deactivated Auto Automatic assignment by the BIOS and operating system Ena...

Page 180: ...n Information If you are not using any PCI Express devices this option should be deactivated Auto Automatic assignment by the BIOS and operating system Enabled Enables this function Disabled Disables...

Page 181: ...ble Interrupt Controller on the PCIE port 3 The IRQ resources available to the system are expanded when the APIC mode is enabled Disabled Disables this function Enabled Enables this function Figure 89...

Page 182: ...ecessary DVMT FIXED Memory Option for setting the amount of memory used for the DVMT mode 64MB 64MB of main memory can be used 128MB 128MB of main memory can be used Maximum DVMT The remaining availab...

Page 183: ...entering The screen content is output centered on the display Expand Text The text is stretched across the entire surface of the display Expand Graphics The graphics are stretched across the entire su...

Page 184: ...ans that when a DVI monitor is connected while the operating system is running it is detected automatically and activated Configuration mode persistence means that for example a dual DVI configuration...

Page 185: ...Core processor Intel R Speedster TM tech Option for controlling the Intel R SpeedStep TM technology The processor clock speed is increased or decreased according to the amount of calculations that mus...

Page 186: ...ult Standard C3 support Enhanced Enhanced C3 support Disabled Disabled C3 support C4 Config Power Management for Intel Core Duo processor Default Standard C4 support Enhanced Enhanced C4 support Disab...

Page 187: ...and Memory Controller Hub supports TS Thermal Sensor in the Thermal Management Algorithm of the DIMM module Disabled Disables this function Enabled Enables this function HighPrecisionEvent Timer The H...

Page 188: ...ted or switched off here HDA Enables High Definition Audio sound AC97 Enables AC 97 sound Disabled Disables the audio controller Table 99 945GME Advanced I O Interface Configuration setting options Ad...

Page 189: ...frequency can be modulated by reducing electromagnetic disturbances Enabled Enables this function Disabled Disables this function Table 100 945GME Advanced Clock Configuration setting options Advanced...

Page 190: ...The serial ATA hard drive is used as a parallel ATA physical memory drive RAID RAID 0 1 5 10 or the Intel Matrix storage technology can be configured here with the serial ATA hard drive AHCI The AHCI...

Page 191: ...ed to the IDE secondary slave port is configured here Enter Opens the submenu See Secondary IDE slave on page 197 Hard disk write protect Write protection for the hard drive can be enabled disabled he...

Page 192: ...d by the system Block Multi Sector Transfer This option enables the block mode for IDE hard drives When this option is enabled the numberof blocks per request from the configuration sector of the hard...

Page 193: ...the Windows device manager in order to guarantee maximum performance Only possible when manually setting up the drive Auto Automatic definition of the transfer rate Disabled Manual definition of the t...

Page 194: ...d by the system Block Multi Sector Transfer This option enables the block mode for IDE hard drives When this option is enabled the numberof blocks per request from the configuration sector of the hard...

Page 195: ...sfer rate S M A R T Monitoring function of modern hard drives self monitoring analysis and reporting technology Auto Automatic detection and enabling Disabled Disables this function Enabled Enables th...

Page 196: ...when supported by the system PIO Mode The PIO mode determines the data rate of the hard drive Information This option is not available on the PPC800 Therefore this setting is not relevant Auto Automa...

Page 197: ...supported by the system Block Multi Sector Transfer This option enables the block mode for IDE hard drives When this option is enabled the numberof blocks per request from the configuration sector of...

Page 198: ...sables this function Enabled Enables this function 32 Bit Data Transfer This function enables 32 bit data transfer Disabled Disables this function Enabled Enables this function Figure 99 945GME Advanc...

Page 199: ...Support USB keyboard support can be enabled disabled here Disabled Disables this function Enabled Enables this function USB Mouse Legacy Support USB mouse support can be enabled disabled here Disable...

Page 200: ...this field you can define the state of the NumLock key when booting Off Only the cursor functions of the numerical keypad are enabled On Numeric keypad is enabled Typematic rate The key repeat functi...

Page 201: ...t mode The serial interface transferrate is defined here as long as disabled is not entered in the remote access field 115200 8 n 1 57600 8 n 1 38400 8 n 1 19200 8 n 1 09600 8 n 1 Value set manually F...

Page 202: ...UTF8 Combo Key Support for the ANSI and VT100 connections can be enabled as long as disabled is not entered in the remote access field Disabled Disables this function Enabled Enables this function Sr...

Page 203: ...own on this page Board temperature Displays the board temperature in degrees Celsius and Fahrenheit None CPU temperature Displays the processor s temperature in degrees Celsius and Fahrenheit None Top...

Page 204: ...12 volt supply None VRTC Displays the battery voltage in volts None Figure 103 945GME Advanced Baseboard Panel Features BIOS setting Meaning Setting options Effect Table 109 945GME Advanced Remote Ac...

Page 205: ...32 Displays the MTCX PX32 firmware version None MTCX FPGA Displays the MTCX FPGA firmware version None CMOS profile Shows the CMOS profile number None Device ID Displays the hexadecimal value of the h...

Page 206: ...F10 Temperature Displays the selected panel s temperature in degrees Celsius and Fahrenheit None Fan speed Displays fan speed for the selected panel None Keys LEDs Displays the available keys and LEDs...

Page 207: ...in the power supply in degrees Celsius and Fahrenheit None Slide in drive 1 Displays the temperature of the slide in drive 1 in degrees Celsius and Fahrenheit None IF slot Displays the temperature of...

Page 208: ...s assigned COM C Setting of the COM port for the touch screen on the monitor panel connector Disabled Disables the interface Enabled Enables the interface Base I O address Selection of the base I O ad...

Page 209: ...is assigned COM E Configuration of the COM port on the B R add on interface Disabled Disables the interface Enabled Enables the interface Base I O address Selection of the base I O address for the CO...

Page 210: ...t priority list allows to select from a list of currently detected 1st Boot Device Primary Master devices 2nd Select Screen Select Item Change Option Quick Boot Enabled F1 General Help Quiet Boot Disa...

Page 211: ...the ROM during the booting procedure Force BIOS An additional BIOS part can be displayed Keep Current BIOS information is displayed Halt On Error This option sets whether the system should pause the...

Page 212: ...is accessed through a program or virus Information With this option only the boot sector is protected not the entire hard drive Disabled Disables this function Enabled Enables this function Hard Disk...

Page 213: ...DD user password This function makes it possible to use the user password to change or configure each hard drive without having to reboot the device A user password allows the user to edit only certai...

Page 214: ...ord This function makes it possible to use the user password to change or configure each hard drive without having to reboot the device Enter Enter password Table 117 945GME Hard Disk Security Master...

Page 215: ...ou to set the energy saving mode for the hard drive Disabled Do not switch off the hard drive Standby Monitor goes to standby mode Suspend Hard drive goes to suspend mode Keyboard PS 2 Mouse The monit...

Page 216: ...ITOR Activities in the IRQ of specific connections or devices return the system to its normal state from power saving mode IGNORE Activities are ignored Secondary Slave IDE The monitoring of activitie...

Page 217: ...system is then rebooted OK Cancel Discard Changes In the event that settings were made which the user can no longer remember changes can be reset as long as they haven t been saved OK Cancel Load CMOS...

Page 218: ...The switch position that is set upon delivery represents the optimum BIOS default values for this system and should therefore not be changed Profile number Optimized for Switch position Note Profile 0...

Page 219: ...dress ETH1 Boot Counter Running Time Table 121 945GME Main profile setting overview Setting View Profile 0 Profile 5 My setting ACPI Aware O S Yes Yes ACPI Version Features ACPI v2 0 ACPI v2 0 ACPI AP...

Page 220: ...lable IRQ7 Available Available IRQ9 Allocated Allocated IRQ10 Available Available IRQ11 Allocated Allocated IRQ12 Available Available IRQ14 Allocated Allocated IRQ15 Allocated Allocated PCI Interrupt...

Page 221: ...IC Enable Disabled Disabled PCIE Port 3 IOxAPIC Enable Disabled Disabled Table 124 945GME Advanced PCI Express configuration profile setting overview Setting View Profile 0 Profile 5 My setting Primar...

Page 222: ...PU configuration profile setting overview Setting View Profile 0 Profile 5 My setting DRAM Frequency Auto Auto Memory Hole Disabled Disabled DIMM Thermal Control Disabled Disabled DT in SPD Disabled D...

Page 223: ...Auto LBA Large Mode Auto Auto Block Multi Sector Transfer Auto Auto PIO Mode Auto Auto DMA Mode Auto Auto S M A R T Auto Auto 32Bit data transfer Enabled Enabled Primary IDE slave Type Auto Auto LBA L...

Page 224: ...Support Enabled Enabled USB Mouse Legacy Support Disabled Disabled USB Storage Device Support Enabled Enabled Port 64 60 Emulation Disabled Disabled USB 2 0 Controller Mode HiSpeed HiSpeed BIOS EHCI H...

Page 225: ...rofile 5 My setting H W Health Function Enabled Enabled Table 134 945GME Advanced CPU Board Monitor profile setting overview Setting View Profile 0 Profile 5 My setting Panel control Select panel numb...

Page 226: ...removable device 5th Boot Device USB removable device USB hard disk 6th Boot Device USB CDROM USB CDROM 7th Boot Device Secondary master Secondary master 8th Boot Device Secondary slave Secondary slav...

Page 227: ...0 Profile 5 My setting Power Management APM Enabled Enabled Suspend Time Out Disabled Disabled Video Power Down Mode Suspend Suspend Hard Disk Power Down Mode Suspend Suspend Keyboard PS 2 Mouse MONI...

Page 228: ...or defect Send industrial PC to B R for checking 6x short 8042 gate A20 failure Keyboard controller defect block 8042 A20 gate Processor cannot switch to protected mode Send industrial PC to B R for c...

Page 229: ...y if ACPI Aware OS is set to YES in the setup TOM 8 MB 192 kB TOM 192 kB N A VGA frame buffer3 3 The VGA frame buffer can be reduced to 1 MB in the setup 1024 kB TOM 8 MB 192 kB 100000h N A Extended m...

Page 230: ...troller 03B0h 03DFh Video system 03E8h 03EFh COM3 03F6h 03F6h Primary IDE channel command port 03F7h 03F7h Primary IDE channel status port 03F8h 03FFh COM1 0480h 04BFh Motherboard resources 04D0h 04D1...

Page 231: ...Optional setting IRQ 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 NMI NONE System timer Keyboard IRQ cascade COM1 Serial port A ACPI1 1 Advanced Configuration and Power Interface Real time clock Coprocessor...

Page 232: ...clock Coprocessor FPU Primary IDE channel Secondary IDE channel B R COM3 COM C COM4 COM E COM5 COM D CAN PIRQ A 2 2 PIRQ A for PCIe UHCI Host Controller 2 VGA controller Intel High Definition Audio Co...

Page 233: ...t 4 B0 D28 F4 PCI EX Port 2 B0 D28 F2 PCI EX Port 3 B0 D28 F3 Native IDE SATA B0 D31 F2 Realtek 8111B B3 D0 F0 PCI EX Slot 5 PCIe bus A B C D PIRQ A APIC IRQ 16 PIRQ B APIC IRQ 17 PIRQ C APIC IRQ 18 P...

Page 234: ...ts to the BIOS setup information about changes can be found in the Readme files of the BIOS upgrade 2 1 1 What information do I need Before you begin the upgrade it helps to determine the various soft...

Page 235: ...ain board panel features Figure 115 Software version Advanced Baseboard Panel Features Versions Panel Control BIOS R115 MTCX PX32 V1 02 MTCX FPGA V1 02 CMOS Profil 0h Device ID 0000AC7h Compatibility...

Page 236: ...an AP Link SDL transmitter 5AC801 SDL0 00 is connected Figure 116 Firmware version of the AP Link SDL transmitter Advanced Panel Control Panel 0 14 connected to Automation Panel Link or Monitor Panel...

Page 237: ...ally upgraded default after 5 seconds Concerning point 2 Returns to the shell MS DOS The system must be rebooted after a successful upgrade Reboot and press Del to enter the BIOS setup menu and load t...

Page 238: ...d using the B R OS Installer then this step is not necessary Connect the bootable media to the PPC800 and reboot the device The boot menu is shown after startup The system must be powered off and on a...

Page 239: ...Automatically upgrade PX32 and FPGA for MTCX default after 5 seconds Concerning point 2 Submenu 1 is opened for upgrading the SDLR controller on the Monitor Panel plug 2 1 Upgrade SDLR on AP 0 AP800...

Page 240: ...el Link Receiver 5DLSDL 1000 00 is connected Automation Panel Link transceivers 5DLSDL 1000 01 or Automation Panel Link receivers 5DLSDL 1000 00 with a Firmware version lower than or equal to V00 10 c...

Page 241: ...disk drive Open Windows Explorer Right click on the 3 floppy icon and select Format Then select the checkbox Create an MS DOS startup disk press Start and acknowledge the warning message with OK Figu...

Page 242: ...iskette In the Explore fo the Tools menu select Folder Options and open the View tab now disable the option Hide protected operating system files Recommended enabled by default and enable the option S...

Page 243: ...ve B R Industrial PC USB Media Drive B R Embedded OS Installer V3 00 or higher 2 4 2 Procedure Connect the USB flash drive to the PC If the drive list is not refreshed automatically the list must be u...

Page 244: ...get MS DOS Information concerning creating an MS DOS boot diskette can be found in section 2 3 Creating an MS DOS boot diskette in Windows XP on page 241 Then the files from the diskette are to be co...

Page 245: ...Industrial PC B R Embedded OS Installer V3 10 or higher 2 5 2 Procedure Insert the CompactFlash card in the CF slot on the industrial PC If the drive list is not refreshed automatically the list must...

Page 246: ...skette can be found in section 2 3 Creating an MS DOS boot diskette in Windows XP on page 241 Then the files from the diskette are to be copied to your hard drive 2 6 Upgrade problems Potential upgrad...

Page 247: ...IOS functions cannot be used Figure 124 Panel PC 800 with MS DOS Model number Short description Note 9S0000 01 010 OEM MS DOS 6 22 German disk OEM MS DOS 6 22 German disks Only delivered with a new PC...

Page 248: ...on the Monitor Panel connector with 945GME CPU boards Resolutions for DVI Color depth 8 bit 16 bit 24 bit 640 x 480 800 x 600 1024 x 768 1280 x 1024 Resolutions for RGB Color depth 8 bit 16 bit 24 bit...

Page 249: ...th a new device 5SWWXP 0600 ENG WinXP Professional with SP3 ENG Microsoft OEM Windows XP Professional Service Pack 3 CD English Only available with a new device 5SWWXP 0600 MUL WinXP Professional with...

Page 250: ...ve device are included Windows XP Embedded is also based on the same reliable code as Windows XP Professional It provides industry with leading reliability improvements in security and performance and...

Page 251: ...ge file Configurable Administrator account User account Configurable Explorer shell Registry filter Internet Explorer 6 0 SP2 Internet information service IIS Terminal service Windows Firewall MSN Exp...

Page 252: ...operating system If an older driver version is installed the latest version can be downloaded from the B R homepage www br automation com and installed A potentially activated Enhanced Write Filter E...

Page 253: ...odules required by the respective device are included Windows XP Embedded Standard 2009 is also based on the same reliable code as Windows XP Professional with SP3 It provides industry with leading re...

Page 254: ...e Administrator account User account Configurable Explorer shell Registry filter Internet Explorer 7 0 Internet information service IIS Terminal service Windows Firewall MSN Explorer Outlook Express A...

Page 255: ...preinstalled on the operating system If an older driver version is installed the latest version can be downloaded from the B R homepage www br automation com and installed A potentially activated Enha...

Page 256: ...es the application hardware independent Applications can be easily ported between B R target systems Cyclic system guarantees deterministic behavior Configurable jitter tolerance in all task classes S...

Page 257: ...rol panel 8 1 Function Adjusting the display specific parameters of connected Panels Reading of device specific keys Figure 128 ADI Control Center Screenshots Examples Information The displayed temper...

Page 258: ...ation using its own setup Windows XP Embedded Content of B R Windows XP Embedded image Windows CE Content of B R Windows CE image Windows Embedded Standard 2009 Content of B R Windows Embedded Standar...

Page 259: ...OS Drivers Updates on the B R homepage www br automation com 1 Download and unzip the ZIP archive 2 Close all applications 3 Run BrSetup exe e g double click on it in Explorer or Right click on BrSetu...

Page 260: ...tion Panel and adapts the DVI signal to various cable lengths The equalizer value is automatically calculated based on the cable length You may set a different equalizer value in order to obtain the b...

Page 261: ...S as well as change update or save the battery settings for the UPS You can also configure the system settings for the UPS Figure 130 ADI Control Center UPS settings Caution The installed UPS must be...

Page 262: ...Click on Apply to begin UPS operation After a few seconds the UPS status and details are displayed 7 Click OK The text field beside System on the UPS tab in the Control Center also indicates whether...

Page 263: ...UPS monitor Information The current status of the UPS is also displayed when the UPS service is started in the Windows Control Panel on the UPS page in the energy options Information In a German vers...

Page 264: ...an change the settings for the UPS battery The changed settings are written to the file by clicking on the OK button The battery settings for the UPS can then be updated with this file Current files w...

Page 265: ...current UPS firmware version 1 10 does not use charge end voltage deep discharge voltage lifespan and deep discharge cycles Lifespan is only included in version 2 and higher of the UPS battery setting...

Page 266: ...sting file and click on Save The transfer can be aborted by clicking on Cancel in the Download dialog box 8 4 6 Configuring UPS system settings 1 Open the Control Center in the Control Panel 2 Select...

Page 267: ...battery shutdown is selected then the UPS will also signal a Low battery alarm in addition to the overcurrent alarm and will turn off after the defined Low battery shutdown time This will allow the op...

Page 268: ...lay see Changing additional UPS settings on page 268 The low battery shutdown time will then be ignored 8 4 7 Changing additional UPS settings 1 Open the Control Center in the Control Panel 2 Select U...

Page 269: ...er rights are required in order to display this dialog box Information This time is evaluated by the Windows UPS Service but can not be set in the UPS system settings of the energy options This value...

Page 270: ...are Automation Device Interface ADI Control Center Panel PC 800 User s Manual V 1 00 Information Regardless of these options all changes to the UPS status are logged in Windows event protocol under Ap...

Page 271: ...ant EN 60068 2 6 Environmental testing part 2 Tests test Vibration sinusoidal EN 60068 2 14 Environmental testing part 2 Tests test N Change of temperature EN 60068 2 27 Environmental testing part 2 T...

Page 272: ...ucted disturbances induced by radio frequency fields EN 61000 4 8 Electromagnetic compatibility EMC part 4 8 Testing and measuring techniques power frequency magnetic field immunity test EN 61000 4 11...

Page 273: ...l scientific and medical ISM radio frequency equipment class A industrial areas EN 55022 Information technology equipment ITE devices class A industrial areas EN 61131 2 Programmable logic controllers...

Page 274: ...60 dB V Average Other connections 150 kHz 500 kHz 97 87 dB V und 53 43 dB A Quasi peak value 84 74 dB V und 40 30 dB A Average Other connections 500 kHz 30 MHz 87 dB V and 43 dB A Quasi peak value 74...

Page 275: ...Quasi peak value Test carried out according to EN 55011 EN 55022 Limits according to EN 61131 2 Limits according to EN 50091 2 class A 30 MHz 230 MHz measured at a distance of 10 m 40 dB V m Quasi pe...

Page 276: ...Electrostatic discharge ESD EN 61000 4 2 EN 61000 6 2 Generic standard industrial areas EN 61131 2 Programmable logic controllers Immunity to high frequency electromagnetic fields HF field EN 61000 4...

Page 277: ...arges criteria B 4 kV 10 discharges criteria B Discharge through the air to plastic housing parts 8 kV 10 discharges criteria B 8 kV 10 discharges criteria B Table 157 Test requirements Electrostatic...

Page 278: ...kV criteria B Unshielded AC I O 3 m 2 kV criteria B Analog I O 1 kV criteria B 1 kV criteria B Table 159 Test requirements High speed transient electrical disturbances burst Test carried out according...

Page 279: ...plitude modulation with 1 kHz length 3 seconds criteria A 150 kHz 80 MHz 3 V 80 amplitude modulation with 1 kHz length 3 seconds criteria A Table 161 Test requirements Conducted disturbances Test carr...

Page 280: ...131 2 AC power inputs max 2 5 kV 1 MHz 10 repeat rate 400 seconds length 2 seconds connection lengths 2 m criteria B DC power inputs max 2 5 kV 1 MHz 10 repeat rate 400 seconds length 2 seconds connec...

Page 281: ...068 2 27 EN 60721 3 2 class 2M1 EN 60721 3 2 class 2M2 EN 60721 3 2 class 2M3 Toppling packaged EN 60068 2 31 EN 60721 3 2 class 2M1 EN 60721 3 2 class 2M2 EN 60721 3 2 class 2M3 Free fall packaged EN...

Page 282: ...its according to EN 61131 2 Limits according to EN 60721 3 3 class 3M4 Shock during operation Pulse half sine stress in all 3 axes x y z Acceleration 15 g length 11 ms 18 shocks Acceleration 10 g leng...

Page 283: ...according to EN 60721 3 2 class 2M3 Free fall Devices with delivery packaging each with 5 fall tests Devices packaged Devices packaged Devices packaged Weight Height Weight Height Weight Height Weight...

Page 284: ...ogic controllers Table 172 Overview of limits and testing guidelines for temperature and humidity Test carried out according to UL 508 Limits according to UL 508 Limits according to EN 61131 2 Worst c...

Page 285: ...is occasionally supplied with voltage during testing duration approximately 30 hours Closed devices These are devices whose data sheet specifies a surrounding housing enclosure with the corresponding...

Page 286: ...of electrical devices Overload UL 508 EN 61131 2 Programmable logic controllers UL 508 Industrial control equipment Simulation component defect UL 508 EN 61131 2 Programmable logic controllers UL 508...

Page 287: ...st over voltage can be removed before the test Input voltage Test voltage Input voltage Test voltage 1 2 50 s voltage surge peak AC 1 min DC 1 min AC 1 min DC 1 min 0 50 VAC 0 60 VDC 850 V 510 V 720 V...

Page 288: ...1 5 IN 1 sec on 9 sec off Table 186 Test requirements Overload Test carried out according to UL 508 Limits according to EN 61131 2 Limits according to UL 508 Simulation of how components in power supp...

Page 289: ...ts and tests Table 189 Overview of limits and testing guidelines for other tests Test carried out according to Limits according to EN 60529 Limits according to EN 60529 Protection of the operating equ...

Page 290: ...zations such as UL CSA FCC VDE VE etc We give special consideration to the reliability of our products in an industrial environment Certifications USA and Canada All important B R products are tested...

Page 291: ...00 02 USB port cap IP65 M20 3 Front side USB port cap attached knurled tall not slotted 5AC900 1200 03 USB port cap IP65 M20 4 Front side USB port cap attached knurled tall slotted 5AC600 UPSI 00 Add...

Page 292: ...SLC NAND flash and IDE ATA interface 5CFCRD 0512 03 CompactFlash 512 MB SSI CompactFlash card with 512 MB SLC NAND flash and IDE ATA interface 5CFCRD 1024 03 CompactFlash 1024 MB SSI CompactFlash car...

Page 293: ...t length 20 m 5CASDL 0250 00 SDL cable 25 m SDL cable for a fixed type of layout length 25 m 5CASDL 0250 03 25 m flex SDL cable SDL cable for fixed and flexible type of layout length 25 m 5CASDL 0300...

Page 294: ...93 Order data Lithium batteries Warning Replace battery with Renata type CR2477N only Use of another battery may present a risk of fire or explosion Battery may explode if mistreated Do not recharge d...

Page 295: ...S batteries Section 6 Accessories 295 Panel PC 800 User s Manual V 1 00 Environment 0AC201 91 4A0006 00 000 Storage temperature 20 to 60 C Relative humidity 0 to 95 non condensing Table 194 Technical...

Page 296: ...tage screw clamps 0TB103 9 0TB103 91 0TB103 91 Plug for the 24 V supply voltage cage clamps Table 195 Order data TB103 Information The following characteristics features and limit values only apply to...

Page 297: ...Manual V 1 00 Resistance between contacts 5 m Nominal voltage according to VDE UL CSA 250 V 300 V Current load according to VDE UL CSA 14 5 A 10 A per contact Terminal size 0 08 mm 3 31 mm Cable type...

Page 298: ...C900 1000 00 This adapter enables a standard monitor to be connected to the DVI I interface 4 1 Order data Model number Description Figure 5AC900 1000 00 Adapter DVI A m to CRT DB15HD f Adapter DVI pl...

Page 299: ...5AC900 1200 01 USB port cap IP65 M20 2 Front side USB port cap attached knurled short not slotted 5AC900 1200 02 USB port cap IP65 M20 3 Front side USB port cap attached knurled tall not slotted 5AC9...

Page 300: ...is activated By integrating the charging circuit in the Panel PC 800 housing the installation has been reduced to merely attaching the connection cable to the battery unit mounted next to the PC Speci...

Page 301: ...ries Communication via integrated interfaces Temperature sensor Driver software Deep discharge protection 6 2 Requirements 1 An appropriate system unit 2 Add on UPS module 5AC600 UPSI 00 3 Battery uni...

Page 302: ...res 5AC600 UPSI 00 Switching threshold mains battery operation 15 13 V Mains failure bridging Max 20 min at 150 W load Charging current Max 0 5 A Deep discharge protection Yes at 10 V on the battery u...

Page 303: ...0 User s Manual V 1 00 Installation The module is installed using the materials included in the delivery Figure 138 Add on UPS module 5AC600 UPSI 00 Installation materials Connection cable Mounting br...

Page 304: ...Max 8 A Deep discharge voltage 10 V Dimensions W x H x D Figure 142 Dimensions 5AC600 UPSB 00 on page 306 Temperature sensor NTC resistance Weight Approx 3 2 kg Ambient temperature Operation Bearings...

Page 305: ...40 Temperature life span diagram Figure 141 Deep discharge cycles Lifespan days 65 70 75 80 25 30 35 40 45 50 55 60 Temperature C 2000 16000 14000 10000 8000 6000 4000 0 Temperature 25 30 35 40 45 50...

Page 306: ...06 Accessories Uninterruptible power supply Panel PC 800 User s Manual V 1 00 Dimensions Figure 142 Dimensions 5AC600 UPSB 00 52 170 5 143 14 104 118 135 30 9 103 8 11 5 4 87 5 166 8 4 All values in m...

Page 307: ...Drilling template Mounting instructions Due to the unique construction of these batteries they can be stored and operated in any position Figure 143 Drilling template for the battery unit General tole...

Page 308: ...5 mm2 AWG 20 4 x 2 5 mm2 AWG 13 Line resistance 0 5 mm2 2 5 mm2 Max 39 km Max 7 98 km Flex radius Fixed installation Free moving 5x wire cross section 10x wire cross section Temperature range Moving...

Page 309: ...the rechargeable UPS batteries power the PC to allow controlled shutdown without loss of data Data and commands are exchanged between the UPS and the load system via the handshake signals for an RS232...

Page 310: ...battery unit type B 24 V 2 2 Ah including battery cage 9A0100 15 UPS battery unit type B replacement part 2 x 12 V 2 2 Ah for battery unit 9A0100 14 9A0017 01 RS232 Null Modem Cable 0 6 m To connect...

Page 311: ...cur during system startup that are caused by the different boot times See chapter 3 Commissioning section 8 Known problems issues on page 163 Information The 5CFCRD xxxx 04 CompactFlash cards are supp...

Page 312: ...es Supported operating modes PIO Mode 0 6 Multiword DMA Mode 0 4 Ultra DMA Mode 0 4 Continuous reading Typically 35 MB s 240X 1 2 Max 37 MB s 260X 1 2 Typically 35 MB s 240X 1 2 Max 37 MB s 260X 1 2 T...

Page 313: ...rature Operation Bearings Transport 0 to 70 C 65 to 150 C 65 to 150 C Relative humidity Operation Storage Transport Max 85 at 85 C Vibration Operation Storage Transport 20 G peak 20 2000 Hz 4 in each...

Page 314: ...nsions CompactFlash card Type I 0 0 10 20 30 40 50 60 70 80 90 80 70 60 50 40 30 20 10 5 10 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 Temperature C Relative humidity RH non condensing 100...

Page 315: ...ark v2 34 comparison writing 5 10 15 20 25 30 35 40 0 5 1 2 4 8 16 32 128 64 256 512 1024 2048 4096 8192 Transfer rate MB s Transfer size kb 5CFCRD 4096 03 5CFCRD 4096 04 5CFCRD 0512 03 5CFCRD 0512 04...

Page 316: ...rtup that are caused by the different boot times See chapter 3 Commissioning section 8 Known problems issues on page 163 Information On Windows CE 5 0 devices 5CFCRD xxxx 03 CompactFlash cards up to 1...

Page 317: ...03 5CFCRD 0512 03 5CFCRD 1024 03 5CFCRD 2048 03 5CFCRD 4096 03 5CFCRD 8192 03 MTBF at 25 C 4 000 000 hours Maintenance None Data reliability 1 unrecoverable error in 1014 bit read accesses Data retent...

Page 318: ...gth Width Thickness 36 4 0 15 mm 42 8 0 10 mm 3 3 0 10 mm Weight 11 4 g Environmental characteristics Ambient temperature Operation Bearings Transport 0 to 70 C 50 to 100 C 50 to 100 C Relative humidi...

Page 319: ...xx 03 Figure 151 Dimensions CompactFlash card Type I 0 0 10 20 30 40 50 60 70 80 90 80 70 60 50 40 30 20 10 5 10 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 Temperature C Relative humidity...

Page 320: ...rresponding short product lifecycle Therefore the following measures might be necessary in order to boot from these flash drives e g the SanDisk Cruzer Micro flash drive with 512 MB The flash drive mu...

Page 321: ...XP and Mac OS 9 1 x OS X v10 1 2 Mechanical characteristics Dimensions Length Width Thickness 52 2 mm 19 mm 7 9 mm Environmental characteristics Ambient temperature Operation Bearings Transport 0 to...

Page 322: ...ters Derating the max ambient temperature typically 1 C per 1000 meters from 500 meters above sea level Figure 152 Temperature humidity diagram USB flash drive 5MMUSB 2048 00 0 0 10 20 30 40 50 60 70...

Page 323: ...cessories 323 Panel PC 800 User s Manual V 1 00 11 B R Automation Studio 3 0USBdongle 11 1 Order data Model number Description Figure 1A4300 LZ1U B R Automation Studio 3 0 USB dongle Dongle for using...

Page 324: ...etail BIOS upgrades for the products Automation PC 620 Panel PC 700 Automation PC 680 Provit 2000 product family IPC2000 2001 2002 Provit 5000 product family IPC5000 5600 5000C 5600C Power Panel 100 B...

Page 325: ...d Interface board Updates Firmware upgrades e g MTCX SMXC Utilities Tools Automation Device Interface ADI Miscellaneous MTC utilities Key editor MTC Mkey utilities Mkey utilities UPS configuration sof...

Page 326: ...n Panel 900 Panel PC 700 Power Panel 15 21 35 41 Power Panel 100 200 Provit 2000 Provit 3030 Provit 4000 Provit 5000 Provit Benchmark Provit Mkey Windows NT Embedded application guide Windows XP Embed...

Page 327: ...le 5CADVI 0xxx 00 similar Caution The DVI cable can only be plugged in and unplugged when the device is turned off Model number Description Note 5CADVI 0018 00 DVI D cable 1 8 m Single cable DVI D m D...

Page 328: ...ction AWG 28 Line resistance Max 237 km Insulation resistance Min 100 M km Flexibility Limited flexibility valid for ferrite magnet ferrite magnet tested 100 cycles with 5x cable diameter 20 cycles mi...

Page 329: ...cording to these specifications Warning If a self built cable is used B R cannot guarantee that it will function properly The DVI cables provided by B R are guaranteed to function properly Figure 156...

Page 330: ...on Note 5CASDL 0018 00 SDL cable 1 8 m SDL cable for a fixed type of layout length 1 8 m 5CASDL 0050 00 SDL cable 5 m SDL cable for a fixed type of layout length 5 m 5CASDL 0100 00 SDL cable 10 m SDL...

Page 331: ...cles 2x DVI D 24 1 male 100 Wire cross section AWG 28 AWG 24 Line resistance Max 237 km Max 93 km Insulation resistance Min 10 M km Flexibility Limited flexibility valid for ferrite magnet ferrite mag...

Page 332: ...Warning If a self built cable is used B R cannot guarantee that it will function properly The SDL cables provided by B R are guaranteed to function properly Figure 159 Pin assignments SDL cable 5CASD...

Page 333: ...ned off Model number Description Note 5CASDL 0018 01 SDL cable 1 8 m 45 SDL cable for fixed type of layout with one sided 45 plug length 1 8 m 5CASDL 0050 01 SDL cable 5 m 45 SDL cable for fixed type...

Page 334: ...AWG 24 Line resistance Max 237 km Max 93 km Insulation resistance Min 10 M km Flexibility Limited flexibility valid for ferrite magnet ferrite magnet tested 100 cycles with 5x cable diameter 20 cycles...

Page 335: ...ons Warning If a self built cable is used B R cannot guarantee that it will function properly The SDL cables provided by B R are guaranteed to function properly Figure 162 Pin assignments SDL cable wi...

Page 336: ...layout length 1 8 m 5CASDL 0050 03 5 m flex SDL cable SDL cable for fixed and flexible type of layout length 5 m 5CASDL 0100 03 10 m flex SDL cable SDL cable for fixed and flexible type of layout len...

Page 337: ...rrite magnet ferrite magnet tested 300 000 cycles with 15x cable diameter 4800 cycles hour Halogen free Yes Flex radius Fixed layout flexible installation See figure Flex radius specification on page...

Page 338: ...50 cycles minute Cable drag chain 300 000 cycles Tested flex radius 180 mm 15x cable diameter hub 460 mm speed 4800 cycles hour Approbation UL AWM 20236 80 C 30 V Oil and hydrolysis resistance Accord...

Page 339: ...lay TMDS data 1 26 AWG TMDS data 2 26 AWG TMDS cycle 26 AWG USB XUSB0 26 AWG XUSB1 26 AWG Data SDL 26 AWG Control wires DDC cycle 24 AWG DDC data 24 AWG 5 V 24 AWG mass 24 AWG Hot Plug detect 24 AWG T...

Page 340: ...10 9 7 6 5 4 2 1 Cable shielding 3 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 7 6 5 4 2 1 Cable shielding 3 DVI 24 1 male DVI 24 1 male 24 17 9 1 17 24 16 8 1 9 8 16 TMDS Clock TMDS Clock TMDS Cl...

Page 341: ...30 m SDL flex cable with extender SDL cable with extender for fixed and flexible type of layout length 30 m 5CASDL 0400 13 40 m SDL flex cable with extender SDL cable with extender for fixed and flexi...

Page 342: ...AWG control wires 26 AWG DVI USB data Line resistance 24 AWG 26 AWG 95 km 145 km Insulation resistance 200 M km Wave impedance 100 10 Test voltage Wire wire Wire shield 1 kVeff 0 5 kVeff Operating vol...

Page 343: ...fication 13 5 4 Dimensions Figure 168 Flex radius specification Figure 169 Dimensions SDL flex cable with extender 5CASDL 0x00 13 Plug Ferrite Ferrite Extender Flex radius Plug Ferrite Flex radius Fer...

Page 344: ...unit for this purpose Connect the end labeled SDL IN with the video output of the Automation PC 620 or Panel PC 800 monitor panel output or Panel OUT of an AP900 AP Link card The SDL OUT end should b...

Page 345: ...ormation Only B R SDL flex cables with extender can be used Figure 171 Pin assignments SDL flex cable with extender 5CASDL 0x00 13 Pin assignments DVI 24 1 male DVI 24 1 male 24 8 17 9 1 24 8 16 16 Ex...

Page 346: ...9 m 5 m RS232 extension cable for remote operation of a display unit with touch screen length 5 m 9A0014 10 RS232 cable DB9 f DB9 m 10 m RS232 extension cable for remote operation of a display unit wi...

Page 347: ...yourself it should be wired according to these specifications Warning If a self built cable is used B R cannot guarantee that it will function properly The RS232 cables provided by B R are guaranteed...

Page 348: ...A type B length 1 8 m 5CAUSB 0050 00 USB 2 0 cable A m B m 5 m USB 2 0 connection cable plug type A type B length 5 m Table 224 Model numbers USB cables Features 5CAUSB 0018 00 5CAUSB 0050 00 Length T...

Page 349: ...want to build a suitable cable yourself it should be wired according to these specifications Warning If a self built cable is used B R cannot guarantee that it will function properly The USB cables p...

Page 350: ...350 Accessories Cables Panel PC 800 User s Manual V 1 00...

Page 351: ...ontrol Center ADI driver but can also be read in a customer application via the ADI Library Information The product design allows the battery to be changed with the PPC800 switched either on or off In...

Page 352: ...ent and carefully pull out the battery using removal strips The battery should not be held by its edges Insulated tweezers may also be used for inserting the battery Insert the new battery with correc...

Page 353: ...be downloaded for free from the download area on the B R homepage www br automation com Figure 177 Temperature sensor locations Position Measurement point for Measurement Max specified 1 Board I O Boa...

Page 354: ...urable using B R Key Editor Advanced desktop operation USB forwarding Daisy chain display operation touch screen USB forwarding Panel locking mechanism configurable using B R Control Center ADI driver...

Page 355: ...erature is reached the device is started at the minimum fan speed The maximum fan speed is reached at a start up temperature of 16 C The fan speed in this area is controlled depending on the temperatu...

Page 356: ...configuration Features Configuration of normal keys like on a keyboard A B C etc Keyboard shortcuts CTRL C SHIFT DEL etc on one key Special key functions change brightness etc Assign functions to LEDs...

Page 357: ...5 Power Panel 100 200 Power Panel 300 400 Mobile Panel 100 200 Mobile Panel 40 50 IPC2000 IPC2001 IPC2002 IPC5000 IPC5600 IPC5000C IPC5600C A detailed guide for configuring keys and LEDs can be found...

Page 358: ...h import libraries for Microsoft Visual C 6 0 and Microsoft eMbedded Visual C 4 0 and Visual Basic for Microsoft Visual Basic 6 0 are supported Features Extensive library of API functions Supported pr...

Page 359: ...e found in the integrated online help The B R Automation Device Interface ADI development kit can be downloaded for free from the download area on the B R homepage www br automation com 4 1 Installati...

Page 360: ...hydrocarbons Toluene Xylene White spirits Trichloroethane Ethyl acetate Diethyl ether N Butyl acetate Amyl acetate Butylcellosolve Ether Acetone Methyl ethyl ketone Dioxan Cyclohexanone MIBK Isophoro...

Page 361: ...1 Panel PC 800 User s Manual V 1 00 6 Viewing angles The viewing angle information of the display types R L U D can be seen in the technical data for the individual components Figure 181 Viewing angle...

Page 362: ...ed operating system APC An abbreviation for Automation PC API Abbreviation for Application Program Interface The interface which allows applications to communicate with other applications or with the...

Page 363: ...ing installation disks to install B R Automation Runtime on the target system Cache Background memory also known as non addressable memory or fast buffer memory It is used to relieve the fast main mem...

Page 364: ...the COM1 port is assigned to IRQ 4 In many systems an RS232 serial mouse is connected to COM1 COM2 Device name for the second serial port in a PC system The input output area for COM2 is usually foun...

Page 365: ...transfer Dial up Data is transferred over the telephone network using a modem or an ISDN adapter DIMM Double In line Memory Module consisting of one or more RAM chips on a small circuit board that is...

Page 366: ...of data than conventional CDs Standard DVDs which have a single layer can hold 4 7 GB Dual layer DVDs can hold 8 5 GB Double sided DVDs can therefore hold up to 17 GB A special drive is needed for DVD...

Page 367: ...ith cycle times down to 200 s and jitter under 1 s This makes Ethernet power available on all communication levels of automation technology from control levels to I O Ethernet POWERLINK was initiated...

Page 368: ...n abbreviation for Flat Panel Controller FPD An abbreviation for Flat Panel Display FTP File Transfer Protocol Rules for transferring data over a network from one computer to another computer This pro...

Page 369: ...Organization for Standardization Worldwide federation of national standardization institutions from over 130 countries ISO is not an acronym for the name of the organization it is derived from the Gr...

Page 370: ...Line Printer Terminal MB Megabyte 1 MB 220 or 1 048 576 bytes Microprocessor Highly integrated circuit with the functionality of a CPU normally housed on a single chip It comprises a control unit arit...

Page 371: ...product range and then distributes these products under its own name OPC OLE for Process Control A communication standard for components in the area of automation The goal of OPC development is to pr...

Page 372: ...ity reaction times are slower compared to connection oriented control Today PLCs are available in device families with matched modular components for all levels of an automation hierarchy PnP An abbre...

Page 373: ...eviation for Quad WUXGA Generally a screen resolution of 3840 2400 pixels 8 5 16 10 RAM An abbreviation for Random Access Memory Semiconductor memory which can be read or written to by the microproces...

Page 374: ...cipants can be connected to an RS485 bus sender receiver RTS An abbreviation for Request To Send A signal used in serial data transfer for requesting send permission For example it is sent from a comp...

Page 375: ...t involved SXGA Abbreviation for Super Extended Graphics Array Graphics standard with a screen resolution of 1280 1024 pixels aspect ratio 5 4 SXGA Abbreviation for SXGA Plus Generally 1400 1050 pixel...

Page 376: ...f a single integrated circuit that combines the circuits required for asynchronous serial communication for both sending and receiving UART represents the most common type of circuit in modems for con...

Page 377: ...oft developed especially for the OEM market It can be ported for various processor types and has a high degree of real time capability The development environment uses proven well established developm...

Page 378: ...378 Appendix A Glossary Panel PC 800 User s Manual V 1 00...

Page 379: ...igure 21 Heat sink 79 Figure 22 Main memory 80 Figure 23 1 slot and 2 slot expansion 81 Figure 24 Expansion description 81 Figure 25 Dimensions Expansion 5PC803 SX01 00 82 Figure 26 Dimensions Expansi...

Page 380: ...tomation Panel 800 via SDL 142 Figure 67 Configuration One AP900 and one AP800 via SDL 145 Figure 68 Configuration Four Automation Panel 900 units via SDL 147 Figure 69 Local connection of USB periphe...

Page 381: ...OS profile hex switch 218 Figure 114 PCI and PCIe routing with activated APIC for CPU boards 945GME version 1 15 233 Figure 115 Software version 235 Figure 116 Firmware version of the AP Link SDL tran...

Page 382: ...ments DVI cable 329 Figure 157 SDL extension cable similar 330 Figure 158 Flex radius specification 331 Figure 159 Pin assignments SDL cable 5CASDL 0xxx 00 332 Figure 160 SDL cable with 45 plug simila...

Page 383: ...Cables 29 Table 21 Model numbers Other items 30 Table 22 Model numbers Software 31 Table 23 Overview of humidity specifications for individual components 41 Table 24 Supply voltage connection 24VDC 4...

Page 384: ...ation One Automation Panel 900 via DVI 137 Table 71 Cables for DVI configurations 137 Table 72 Possible Automation Panel units resolutions und segment lengths 137 Table 73 Possible combinations of sys...

Page 385: ...ord 213 Table 117 945GME Hard Disk Security Master Password 214 Table 118 945GME Power Menu Setting options 215 Table 119 855GME XTX Exit menu Setting options 217 Table 120 Profile overview 218 Table...

Page 386: ...s with electrical frequencies 279 Table 163 Test requirements Voltage dips fluctuations and short term interruptions 279 Table 164 Test requirements Damped oscillatory waves 280 Table 165 Overview of...

Page 387: ...Table 208 Technical data USB flash drive 5MMUSB 2048 00 321 Table 209 Order data B R Automation Studio 3 0 Dongle 323 Table 210 Order data HMI Drivers Utilities DVD 324 Table 211 Model numbers DVI ca...

Page 388: ...Table index 388 Panel PC 800 User s Manual V 1 00...

Page 389: ...I 0050 00 29 292 327 5CADVI 0100 00 29 292 327 5CASDL 0018 00 29 292 330 5CASDL 0018 01 29 292 333 5CASDL 0018 03 29 292 336 5CASDL 0050 00 29 293 330 5CASDL 0050 01 29 293 333 5CASDL 0050 03 29 293 3...

Page 390: ...B945 14 24 78 5PC820 1505 00 24 66 5PC820 1906 00 24 72 5SWHMI 0000 00 31 324 5SWWXP 0427 ENG 31 250 5SWWXP 0500 ENG 31 249 5SWWXP 0500 GER 31 249 5SWWXP 0500 MUL 31 249 5SWWXP 0600 ENG 31 249 5SWWXP...

Page 391: ...onfiguration 189 CPU board monitor 203 CPU configuration 185 Exit 217 Graphics configuration 181 Hard disk security master password 214 Hard disk security user password 213 I O interface configuration...

Page 392: ...on standards 23 Dimensions Standard half size PCI card 84 Standard half size PCIe card 84 DIMM 365 Disposal 22 Distribution of resources 229 I O address assignment 230 RAM address assignment 229 DMA 3...

Page 393: ...eat cyclic 285 Humidity specifications 41 I IDE 368 Image sticking 164 Immunity 276 Individual components 66 Bus unit 86 CPU board 78 Drives 95 Heat sink 79 Main memory 80 Slide in compact HDD 95 98 S...

Page 394: ...ards 89 Ethernet card 90 POWERLINK card 2 port 92 PnP 372 POH 372 POST 372 Post codes 228 Power 58 Power button 60 Power calculation PPC800 19 43 44 Power fail 58 Power management 42 POWERLINK 372 Car...

Page 395: ...protection 302 Short term interruptions 279 Slide in compact slot 64 Slide in slot 1 85 Slot PLC 374 Smart Display Link 50 Soft off 58 SoftPLC 375 Software 167 Sound 56 Standard keypad module 375 Sta...

Page 396: ...ical data 320 USB flash drive for B R update files 243 USB interfaces 54 USB peripheral devices 152 USB port cap 299 USB5 55 UXGA 377 V VGA 377 Vibration during transport 282 Vibration operation 281 V...

Reviews: