![B&D Controll-A-Door R Instruction Manual Download Page 24](http://html.mh-extra.com/html/bandd/controll-a-door-r/controll-a-door-r_instruction-manual_460090024.webp)
Diagnostic Code
Action
2-1
2-2
2-3
2-4
3-1
or
more
While the opener is flashing an error code it will not respond to a remote control signal, nor can it learn codes or limits.
The opener can be reset from error mode by either:
•
interrupting the mains power,
•
operating a previously coded remote control transmitter; or
•
by pressing the operate button.
2 flashes
1 flash
2 flashes
2 flashes
SERVICE
POWER
For Product Support contact 1800 636 407
Patents Apply
SERVICE
POWER
For Product Support contact 1800 636 407
Patents Apply
2 flashes
3 flashes
SERVICE
POWER
For Product Support contact 1800 636 407
Patents Apply
2 flashes
4 flashes
SERVICE
POWER
For Product Support contact 1800 636 407
Patents Apply
3 flashes
1 flash
SERVICE
POWER
For Product Support contact 1800 636 407
Patents Apply
Remains On
SERVICE
POWER
For Product Support contact 1800 636 407
Patents Apply
Check the wiring to the Safety Infra Red
Beams. The wiring may be short circuit or
open circuit. If there are no faults in the
wiring the IR Beam detectors may need
servicing or replacing.
The operate button in the light cover
is stuck – remove the light cover and check
that the operate button is not stuck. An
external operate button is shorted – remove
the accessory plug to identify fault.
The Limit Set button is stuck – contact an
authorised dealer for service.
An external limit set button is shorted –
remove the light cover and remove the
accessory plug.
If fault remains contact an authorised dealer
for service.
The Code Set button may be stuck down.
Try pressing the button or reset the opener.
If problem persists contact an authorised
dealer for service
3-1 or more flashes indicates an internal
electronic fault has occurred.
Call an authorised dealer for service
The Code Set LED will illuminate whenever a
433MHz signal is being transmitted. If the Code
Set LED stays on it indicates that there is possibly
a 433MHz remote control transmitter with a
button stuck on. To identify the faulty remote
control transmitter, remove the battery from each
transmitter checking the Code Set LED each time.
When the battery is removed from the faulty
transmitter the Code Set LED will go out.
If the Service LED is ON it indicates the door is
overdue for service.
If the Service LED is flashing it indicates the door
and/or opener may need urgent attention.
The courtesy light will also flash five times each
time the door is operated whilst the Service LED
is illuminated.
Contact an authorised dealer.
Flashes
Continuously
SERVICE
POWER
For Product Support contact 1800 636 407
Patents Apply
24
©Copyright 2003
Part No 059778