SECTION 5 - MAINTENANCE
5.1 Maintenance
The Service LED will indicate the requirement for service
and/or adjustment. Whilst the Service LED is illuminated
the courtesy light will flash five times each time the door
is operated until the Service LED is reset.
To reset the Service LED when the door is serviced,
reprogram the Door Travel Limits and the Door Travel
Force – on completion of this programming the Service
LED will go out.
Whilst your opener does not require any periodic maintenance, the door that it is fitted to does. Your garage door is
a large, heavy, moving object and should be tested regularly to ensure it is in good condition. A poorly maintained
door could cause fatal or serious injuries.
To ensure long and trouble free life of your opener the following is recommended:
5.2 Monthly
•
Disengage the opener and manually operate the door. The door must be smooth to operate by hand, and
operating force on the bottom rail should not exceed 200 Newtons (20kg) force.
•
Each month check that the opener reverses when the door contacts a 40mm high object placed on the floor.
(AS3350). Refer to Testing the Safety System.
If the door does not operate smoothly, call your nearest Authorised Dealer.
5.3 Yearly
•
We suggest that you contact your nearest Authorised Dealer to perform annual door service.
Warning:
Failure to maintain your garage door may void the warranty on your garage door
opener.
Record any services in the following table to assist in any warranty service.
Date
Service Performed By
Signature
Amount
Invoice No.
Frequently examine the installation, in particular cables, springs and mountings, for
signs of wear, damage or imbalance. Do not use if repair or adjustment is needed
since a fault in the installation or an incorrectly balanced door may cause injury.
AS3350
Adjustments should only be carried out by experienced persons, as this function can
be dangerous if not performed under strict safety procedures.
©Copyright 2003
21
Part No 059778
SERVICE
POWER
For Product Support contact 1800 636 407
Patents Apply
Service
Indicator
LED