64
Operation
Switch the transmitter off by pressing the ON/OFF switch
towards "OFF" (O).
Switch the transmitter back on by pressing the ON/OFF
switch towards "ON" (I).
The siren and the "Emergency" output are switched off. The
alarm is reset.
17 3 15 Switch off "Passive emergency"
If you switch off the passive emergency monitoring
once the deactivation is saved (even with the transmit-
ter or receiver switched off). Then
no more emergency
calls
are transmitted with passive emergency criteria.
If the function is required again then it must be reac-
tivated.
Status LED
Operating level LED
Switch off "Passive emergency"
The transmitter must be switched off.
Press the switch ("Release brake") towards the body and
hold the switch in this position.
Press the switch ("Gas –") towards the body and hold the
switch in this position.
Press the ON/OFF switch towards "ON" (I) and keep it in this
position.
Status LED lights up green.
Operating level LED lights up orange.
Let go of all 3 switches so that they go back to their resting
position.
The operating level LED lights up red and the siren is trigge-
red briefly twice.
Passive emergency is deactivated and the transmitter swit-
ches itself off again.
Switch the transmitter back on (see operation / F10 S
transmitter) as soon as you want to resume your work.
Details: See function description / functions / function passive
emergency call ("passive emergency")