40
Connections and Interfaces
12 3 Connection configuration
The connections of sockets 1 and 2 are already prewired at the factory to one or several vehicle connectors. The assignment is based
on the winch type and is attached to the wireless control.
12 3 1 Socket 1
1 2 3 4 5 6 7 8
Socket 1 connection configuration
Pin
Type
Labeling / icon
Function
Technical Data
1
Output
NOT
In the event of emergency off to trigger a loud
horn / private mobile wireless device
SwU
B
/ max. 5 A
2
Output
P
Optional EMERGENCY potential-free
3
Output
Motor STOP
4
Output
B
Additional command B
5
Output
SIR
Siren (pre-alarm, main alarm)
6
Output
Release brake right (only for F10 DT)
7
Output
Pull drum right (only for F10 DT)
8
Output
Pull drum (for F10 DT left)
Table: Socket 1 connection configuration
Do not apply any voltage to the outputs!