4 / 18
0006081362_200806
E
N
G
L
I
S
H
STANDARD ACCESSORIES
TECHNICAL DATA
TBG 45
TBG 45P
TBG 60
TBG 60P
THERMIC CAPACITY
MAX kW
450
600
MIN kW
100
120
OPERATION
One stage
Two stages
One stage
Two stages
NOx EMMISION
mg/kWh
< 80 (Classe III secondo EN 676)
MOTOR
kW
0,50
0,75
r.p.m.
2730
2800
ABSORBED ELECTRICAL POWER*
kW
0,67
0,69
0,93
0,96
line fuse
A / 400 V
- -
4
IGNITION TRANSFORMER
26 kV - 40 mA - 230/240 V - 50/60 Hz
VOLTAGE
1N ~ 230 V ±10%- 50 Hz
3N ~ 400 V ±10%- 50 Hz
PROTECTION RATING
IP 44
FLAME DETECTOR
IONIZATION PROBE
NOISE**
dBA
73
75
WEIGHT
kg
40
42
Natural Gas (G 20)
FLOW RATE
MAX
m³n/h
45,3
60,3
MIN
m³n/h
10,1
12,1
GAS PRESSURE
MAX
mbar
360
*)
Total absorption at start with ignition transformer on. .
**) Noise levels measured by the manufacturer in the laboratory with burner running on test boiler, at maximum nominal thermal output.
TBG 45
TBG 45P
TBG 60
TBG 60P
BURNER FIXING FLANGE
2
2
2
2
ISOLATING GASKET
1
1
1
1
STUD BOLTS
N° 4 M 12
N° 4 M 12
N° 4 M 12
N° 4 M 12
EXAGONAL NUTS
N° 4 M 12
N° 4 M 12
N° 4 M 12
N° 4 M 12
FLAT WASHERS
N° 4 Ø 12
N° 4 Ø 12
N° 4 Ø 12
N° 4 Ø 12