background image

 

                                                                                                                

Sig Marine Products  

                                                                                                                  #101-17728 66 Ave  

                                                                                                        Surrey B.C. 

                                                                                                               Canada V3S 7X1 

                                                                                                                   

www.sigmarine.com

 

                                                                                                                     

[email protected]

 

                                                                                                              

                                                                                                                     

 

 

                                                                              

 

Cozy Cabin Heater Propane 

Bottom

 Assembly 

                                       

#10400

 

 
 

 

 

 

Instruction Manual 

 

This manual must be read and the requirements carried out 

to ensure satisfactory performance. 

 

SIG MARINE RESERVES THE RIGHT TO MAKE CHANGES TO PRODUCTS 

OR  DOCUMENTS AT ANY TIME 

 

 

 

 

Summary of Contents for 10400

Page 1: ...marine com info sigmarine com Cozy Cabin Heater Propane Bottom Assembly 10400 Instruction Manual This manual must be read and the requirements carried out to ensure satisfactory performance SIG MARINE RESERVES THE RIGHT TO MAKE CHANGES TO PRODUCTS OR DOCUMENTS AT ANY TIME ...

Page 2: ...W PRESSURE PROPANE GAS APPLIANCE YOU MUST HAVE A SEPARATE 11 W C LOW PRESSURE REGULATOR INSTALLED CORRECTLY OR OPERATION WILL RESULT IN A DANGEROUS FIRE AND WILL DAMAGE YOUR UNIT PLEASE READ YOUR INSTRUCTION MANUAL BEFORE USE OF THIS APPLIANCE SIG MARINE PROPANE BOTTOM ASSEMBLY ...

Page 3: ...al help we ask that you contact your dealer or Sig Marine quoting both the model and serial number printed on the product identification label SAFETY AND INSTALLATION General The Cozy Cabin Heater Bottom Assembly 10400 is manufactured for the Model 10000 and is designed to be fuelled only by low pressure liquid propane gas LPG If compressed natural gas CNG is used in this heater the burner flame w...

Page 4: ... cylinder right side up to ensure that liquid withdrawal does not occur a We recommend that a solenoid valve which can be controlled by a switch located in your cabin be installed next to the manual cylinder valve The cylinder valve outlet and the 9V or 12V DC solenoid valve should be clean and dry when they are connected to each other 5 Unnecessary attempts to seal this connection with substances...

Page 5: ...een an existing appliance and the gas cylinder to feed another appliance You may install a T connection only within the fuel tank s enclosure so any leakage is contained 11 Be sure you do not kink the hose or piping connecting the regulator with the range by bending it too sharply during installation 12 Protect the hose against vibration and damage by securing it tightly to bulkheads and hull side...

Page 6: ...ion of half liquid soap and half water check each gas connection one at a time by brushing the soap and water solution over all the connections Presence of bubbles indicates a leak Tighten fitting and re check for leaks Do not use an open flame to check for gas leaks 2 The first time you use your heater you will have to purge the air out of the supply lines before it will light Turn the knob to th...

Page 7: ...th manual and solenoid cylinder valves immediately Make sure that the appliance valve is closed 2 Ventilate all interior compartments thoroughly Maintaining as much ventilation as possible open cylinder valves Make sure that the appliance valve is still closed Apply a mixture of liquid detergent and water to all connections checking for bubbles indicating a leak Do not use a flame to check for lea...

Page 8: ...ke attachment protruding into the pilot flame is one end of the thermocouple 3 Check first that the thermocouple is screwed into the valve tightly enough A loose connection will not transfer the 1 5 millivolt If it has been tightened too much the insulating washer will have been crushed shorting out the thermocouple and so will not generate the 1 5 millivolt It must therefore be replaced 4 Heaters...

Page 9: ......

Page 10: ...of purchase The buyer shall be responsible for shipping and insurance charges if any on the products returned for repair under the terms of this warranty This limited warranty applies only to products that have been installed and used in accordance to printed instructions of Sig Marine Company and does not cover improper use vandalism negligence or accidents As some states do not allow limitations...