4
PRODUCT
DESCRIPTION
22
www. matrix-vision.com
BVS SC-_1280Z00-30-0-0
SMART
CAMERA
Fieldbus
www.balluff.com
PROFINET
LED
Indicator
Function
Fieldbus 1
MS: Bus Failure
Off
No fault or no voltage
Red flashing
No data exchange or no configuration
Red on
PROFINET IO not configured or not
connected
Fieldbus 2
NS: System Failure
Off
No fault or no voltage
Red on
PROFINET IO not ready
Fieldbus 1
and Fieldbus 2
Both LEDs flashing
red
DCP signal service enabled
EtherNet/IP
LED
Indicator
Function
Fieldbus 1
NS: Network Status
Off
No voltage or no IP address
Green
Connection made
Green flashing
No connection made
Red
Duplicate IP address
Red flashing
Connection timeout
Red - Green flashing
Self-test after switch-on
Fieldbus 2
MS: Module Status
Off
No voltage
Green
Device is ready for operation
Green flashing
Device not configured
Red
Severe, fatal error
Red flashing
Simple, rectifiable error
Red - Green flashing
Self-test after switch-on