4
PRODUCT
DESCRIPTION
19
www. matrix-vision.com
BVS SC-_1280Z00-30-0-0
SMART
CAMERA
Fieldbus
www.balluff.com
Output connection
If I/O 0 is configured as output, the supply voltage is applied at the output and the actua-
tor, PLC input is supplied with it if 1 is being output. The output is connected with GND if
0 is being output. The output current of an I/O may not exceed 100 mA.
If the output is being overloaded, e.g. by a short circuit, it is switched off and periodically
checked whether the fault occurrence is still present. If the error was removed, the output
is again in normal operating state without a reset.
PNP output connection
PNP logic is predominantly used in Europe. The output is sourcing, so that the load
between I/O and GND must be switched accordingly. The load is connected with supply
voltage if 1 is being output.
Figure 5 PNP output connection
NPN-Ausgangsbeschaltung
NPN logic is predominantly used in Asia. The output is sinking, so that the load between
I/O and supply voltage must be switched accordingly. The load is set to GND if 0 is being
output.
To obtain a normal switching behavior, the output can be inverted.
Figure 6 NPN output connection
The LAN interface meets the Ethernet standard in accordance with IEEE 802.3-2008 (up
to 1 Gigabit). This network connection is used to call up the web interface BVS Cockpit
for the configuration. In addition, a communication channel is available to control the
image analysis and to call up the generated result values.
4.4.3 LAN