6
STARTUP
36
www. matrix-vision.com
BVS SC-_1280Z00-30-0-0
SMART
CAMERA
Fieldbus
www.balluff.com
PROFINET fieldbus
Setting and Dis-
plays
Description
Version
Version of fieldbus firmware (for service purposes only)
MAC addresse
Basic MAC address of the fieldbus
Handshake timeout
This setting activates a 500-ms timeout for the handshake of the
process data
Station name
Name of the fieldbus device
IP address
Fieldbus IP address, assigned by the PLC
Subnet mask
Fieldbus subnet mask, assigned by the PLC
IO-Link mode
Defines how the IO-Link master port is used
The communication between the
SMARTCAMERA
and the host system is done via
PROFINET IO.
The system PROFINET IO consists of the following components:
•
IO controller (e.g. PLC)
•
IO device (here the SMARTCAMERA)
In a PROFINET network, IO controllers and IO devices are connected to each other
using all common network topologies: star, line, ring or tree type topologies are possible.
Device master data
To parameterize the IO controller true to type, the device master data in form of a
GSDML file are needed. The file is located on the Balluff website (see