18
english
6.3.3 Parameter data
The device can be completely configured by setting the parameter data (see table below):
Tab. 6-6: Parameter data
* refers to the light band length L in 0.1 mm step (See Tab. 4-2).
6
IO-Link interface (continued)
Index
Name
Sub-
index
Size
Access
Range of values/
Bit No.
Default
setting
Note
0x0C
Lock settings
Bitmaske:
UINT16
R/W
Locking parameter write access
R/W
Bit 0
0
0 … unlocked 1 … locked
Locking data storage
R/W
Bit 1
0
0 … unlocked 1 … locked
- Device Lock
R/W
Bit 2
0
0 … unlocked 1 … locked
- Keyboard Lock
R/W
Bit 3
0
0 … unlocked 1 … locked
0x50
Display Parameter
- Sleep Time
1
UINT8
R/W
0-2
0
0 … 1 min 1 … 5 min 2 … 15 min
- Rotation
2
UINT8
R/W
0-1
0
0 … unlocked 1 … locked
- Contrast
3
UINT8
R/W
0-23
0
0x64
Blanking
- Blanking left
1
UINT32
R/W
0-L*
0
Value in 0.1 mm steps
- Blanking right
2
UINT32
R/W
0-L*
0
Value in 0.1 mm steps
- Blanking active
3
UINT8
R/W
1
0 … unlocked 1 … locked
0x65
Analog output value 1
- Mode
1
UINT8
R/W
0-8
1
Assignment (See Tab. 4-1)
- Averaging
2
UINT16
R/W
0
Number of measurements
- Scaling
3
FLOAT
R/W
1.0
Scaling factor
- Offset
4
INT32
R/W
0
Offset value
0x66
Analog output value 2
- Mode
1
UINT8
R/W
0-8
3
Assignment (See Tab. 4-1)
- Averaging
2
UINT16
R/W
0
Number of measurements
- Scaling
3
FLOAT
R/W
1.0
Scaling factor
- Offset
4
INT32
R/W
0
Offset value
0x68
Object output value
- Mode
1
UINT8
R/W
0-10
5
Assignment (See Tab. 4-1)
- Object diameter or slot width for
simultaneous object counting
2
UINT16
R/W
0-L*
0
Value in 0.1 mm steps
- Tolerance for simultaneous
object counting
3
UINT16
R/W
0-L*
0
Value in 0.1 mm steps
0x69
Object detection / characteristic value
- Object 1
1
UINT16
R/W
0-L*
0
Value in 0.1 mm steps
- Object 2
2
UINT16
R/W
0-L*
0
Value in 0.1 mm steps
- Object 3
3
UINT16
R/W
0-L*
0
Value in 0.1 mm steps
- Object 4
4
UINT16
R/W
0-L*
0
Value in 0.1 mm steps
- Object 5
5
UINT16
R/W
0-L*
0
Value in 0.1 mm steps
- Object 6
6
UINT16
R/W
0-L*
0
Value in 0.1 mm steps
0x6A
Object detection Tolerance
- Object 1
1
UINT16
R/W
0-L*
0
Value in 0.1 mm steps
- Object 2
2
UINT16
R/W
0-L*
0
Value in 0.1 mm steps
- Object 3
3
UINT16
R/W
0-L*
0
Value in 0.1 mm steps
- Object 4
4
UINT16
R/W
0-L*
0
Value in 0.1 mm steps
- Object 5
5
UINT16
R/W
0-L*
0
Value in 0.1 mm steps
- Object 6
6
UINT16
R/W
0-L*
0
Value in 0.1 mm steps
BLA Series D