Secondary Device Functions (continued)
6.5
Basic Statistics
6.5.1 Description
With the
Basic Statistics
function, statistics processes can
be executed, such as the calculation of minimum,
maximum and average. Furthermore, it is possible to
calculate the moving average.
With
Basic Statistics
, trends can be displayed for the
selected entry over the specified duration (between
1 second and 1 week or 1 to 1000 sampling points).
6.5.2 Mathematics/Algorithm
Fig. 6-5 displays the realistic view of the calculation of
minimum value, maximum value and average.
Fig. 6-5:
Average
Input
Maximum
Minimum
Calculation of minimum, maximum and average
As shown in Fig. 6-5, the calculation is initiated by the start
command and stopped by the stop command. The values
are kept between start and stop until a reset is performed.
If the operating voltage is switched off, the current values
are not stored and, as a result, are reset on the next start.
Fig. 6-6 shows how the calculation of the moving average
functions with the periodic window approach. The average
is calculated for each periodic window, whereby the size of
the window can be set. As shown, the average is
calculated repeatedly for a window size of 5 elements. It
must be mentioned that the windows do not overlap.
BOS R254K-UUI-RH10-S4
Photoelectric Sensors
Summary of Contents for BOS R254K-UUI-RH10-S4
Page 1: ...deutsch Konfigurationsanleitung english Configuration Guide BOS R254K UUI RH10 S4...
Page 2: ...www balluff com...
Page 3: ...BOS R254K UUI RH10 S4 Konfigurationsanleitung deutsch...
Page 4: ...www balluff com...
Page 108: ......
Page 109: ...BOS R254K UUI RH10 S4 Configuration Guide english...
Page 110: ...www balluff com...