www.balluff.com
27
english
Event Code Event Type
Description
Device Status
0x8D12
(36114)
Warning
The defined threshold of the device-internal humidity
was exceeded.
►
Check installation and ambient conditions.
1 – Maintenance-Required
0x8D13
(36115)
Warning
One or more extreme conditions present.
0 – Device is operating properly.
0x8D20
(36128)
Warning
Device Temperature Lower Warning
– The device
temperature has fallen below the set lower
temperature warning threshold.
0 – Device is operating properly.
0x8D22
(36130)
Warning
Warning limit for write cycles reached – maintenance
monitoring no longer guaranteed – for information
purposes only.
0 – Device is operating properly.
0x8D23
(36131)
Error
Write cycle limit reached – saving no longer ensured
– replacement recommended.
1 – Maintenance-Required
0x8D24
(36132)
Warning
Parameter write error – for information purposes
only.
0 – Device is operating properly.
0x8D25
(36133)
Error
Parameters not consistent – basic settings are used,
service required. Parameterization processes and
resets can no longer be performed.
4 – Failure
0x8DC0
(36288)
Notification
Teach-in Timeout
– The current teach-in process
took too long and was interrupted.
0 – Device is operating properly.
Tab. 3-4: Events – Overview
3
Overview of IO-Link Data and Functions (continued)
BOS R254K-UUI-RH10-S4
Photoelectric Sensors
Summary of Contents for BOS R254K-UUI-RH10-S4
Page 1: ...deutsch Konfigurationsanleitung english Configuration Guide BOS R254K UUI RH10 S4...
Page 2: ...www balluff com...
Page 3: ...BOS R254K UUI RH10 S4 Konfigurationsanleitung deutsch...
Page 4: ...www balluff com...
Page 108: ......
Page 109: ...BOS R254K UUI RH10 S4 Configuration Guide english...
Page 110: ...www balluff com...