28
english
In Tab. 4-1 the basic IO-Link specification of the standard
variant BOS R254K-UUI-RH10-S4 (ADSS) is described.
Specification
IO-Link Description
Value
Transmission rate
COM
COM3 (230,4 kBaud)
Minimum cycle time of device
min cycle time
0x1E (3 ms)
Frame specification:
– Amount of
Preoperate
on demand data required
– Amount of
Operate
on demand data required
– ISDU
M-sequence capability:
– Preoperate M-sequence type
– Operate M-sequence type
– ISDU supported
0x11
2 Byte
1 Byte
supported
IO-Link protocol version
Revision ID
0×11 (Version 1.1)
Amount of process data from the device to the master
ProcessDataIn
0x41 (1 Byte)
Amount of process data from the master to the device
ProcessDataOut
0x01 (1 Byte)
Manufacturer ID
Vendor ID
0×378
Device identification
Device ID
0x040B10
Tab. 4-1: Communication parameters
In order to flexibly adapt the basic communication
parameters to the application, other device variants can
also be adjusted (see Tab. 4-2 on page 28).
The following device variants can be selected (also see
Variant name
Device
identifica-
tion
Transmission
rate
Minimum
cycle
time of
device
Frame specification
(Number of
Preoperate on
demand data
required / Number
of Operate on
demand data
required / ISDU)
IO-Link
protocol
version
Qty. of process
data
from
the
device
to the
master
from
the
master
to the
device
BOS R254K-UUI-
RH10-S4 (ADSS)
0x040B10
COM3
(230,4 kBaud)
3 ms
0x11 (2 Byte/1 Byte/
supported)
0x11
(Version 1.1)
1 Byte
1 Byte
BOS R254K-UUI-
RH10-S4 (LSSC)
0x040B11
COM3
(230,4 kBaud)
3 ms
0x11 (2 Byte/1 Byte/
supported)
0x11
(Version 1.1)
1 Byte
1 Byte
BOS R254K-UUI-
RH10-S4 (CM)
0x040B12
COM3
(230,4 kBaud)
5 ms
0x19 (2 Byte/1 Byte/
supported)
0x11
(Version 1.1)
17 Byte
1 Byte
BOS R254K-UUI-
RH10-S4 (CNT)
0x040B13
COM3
(230,4 kBaud)
5 ms
0x19 (2 Byte/1 Byte/
supported)
0x11
(Version 1.1)
6 Byte
1 Byte
BOS R254K-UUI-
RH10-S4 (CCM)
0x040B30
COM3
(230,4 kBaud)
5 ms
0x19 (2 Byte/1 Byte/
supported)
0x11
(Version 1.1)
17 Byte
1 Byte
Tab. 4-2: Communication parameters – Device variants
4
Communication parameters
BOS R254K-UUI-RH10-S4
Photoelectric Sensors
Summary of Contents for BOS R254K-UUI-RH10-S4
Page 1: ...deutsch Konfigurationsanleitung english Configuration Guide BOS R254K UUI RH10 S4...
Page 2: ...www balluff com...
Page 3: ...BOS R254K UUI RH10 S4 Konfigurationsanleitung deutsch...
Page 4: ...www balluff com...
Page 108: ......
Page 109: ...BOS R254K UUI RH10 S4 Configuration Guide english...
Page 110: ...www balluff com...