www.balluff.com
19
english
Name
Index
Sub-
index
Access
Length
Data Type
Data
Storage
Default
Signal Speed Monitoring
Switching Speed
0x009B
(155)
0
R/W
12 bytes
Yes
Input
1
R/W
2 bytes
UINT16(ENUM)
No
0
Mode
2
R/W
1 byte
UINT8(ENUM)
No
0
Speed Upper Limit
High
3
R/W
2 bytes
UINT16
No
100
Speed Upper Limit
Low
4
R/W
2 bytes
UINT16
No
85
Speed Lower Limit
High
5
R/W
2 bytes
UINT16
No
65
Speed Lower Limit
Low
6
R/W
2 bytes
UINT16
No
50
Startup Delay
7
R/W
1 byte
UINT8
No
0
Switching Speed
Status
0x009C
(156)
0
R
3 bytes
n/a
State
1
R
1 byte
UINT8(ENUM)
n/a
–
Value
2
R
2 bytes
UINT16
n/a
–
Switching Counter
Switching Counter
0x00B6
(182)
0
R/W
6 bytes
Yes
Input
1
R/W
2 bytes
UINT16(ENUM)
No
0
Mode
2
R/W
1 byte
UINT8(ENUM)
No
0
Limit
3
R/W
2 bytes
UINT16
No
2
Startup Delay
4
R/W
1 byte
UINT8
No
0
Switching Counter
Status
0x00B7
(183)
0
R
3 bytes
n/a
State
1
R
1 byte
UINT8(ENUM)
n/a
–
Value
2
R
2 bytes
UINT16
n/a
–
Basic Statistics
Statistics Data
Configuration
0x0426
(1062)
0
R/W
8 bytes
Yes
–
Input Signal
1
R/W
2 bytes
UINT16(ENUM)
No
–
Time Period Unit
2
R/W
1 byte
UINT8(ENUM)
No
Seconds
Time Period Value
3
R/W
2 bytes
UINT16
No
1
Moving Average
Window Unit
4
R/W
1 byte
UINT8(ENUM)
No
Measurement values
Moving Average
Window Value
5
R/W
2 bytes
UINT16
No
100
Statistics Data Output
0x0427
(1063)
0
R
21 bytes
n/a
Minimum
1
R
4 bytes
FLOAT32
n/a
–
Maximum
2
R
4 bytes
FLOAT32
n/a
–
Average
3
R
4 bytes
FLOAT32
n/a
–
Moving Average
4
R
4 bytes
FLOAT32
n/a
–
Number Of Samples
5
R
4 bytes
UINT32
n/a
–
Status
6
R
1 byte
UINT8
n/a
–
3
Overview of IO-Link Data and Functions (continued)
BOS R254K-UUI-RH10-S4
Photoelectric Sensors
Summary of Contents for BOS R254K-UUI-RH10-S4
Page 1: ...deutsch Konfigurationsanleitung english Configuration Guide BOS R254K UUI RH10 S4...
Page 2: ...www balluff com...
Page 3: ...BOS R254K UUI RH10 S4 Konfigurationsanleitung deutsch...
Page 4: ...www balluff com...
Page 108: ......
Page 109: ...BOS R254K UUI RH10 S4 Configuration Guide english...
Page 110: ...www balluff com...