26
english
6
IO-Link interface (continued)
6.2.7 Relative humidity
The sensor is equipped with humidity monitoring (index
0x2041 (8257)). The humidity (subindex 0x01 (1)) and the
minimum and maximum values since the last startup
(subindex 0x02 (2) and 0x03 (3)), since production
(subindex 0x04 (4) and 0x05 (5)) and since the last manual
reset (subindex 0x06 (6) and 0x07 (7)) are measured. The
values in index 0x2031 (8257), subindex 0x02 (2), 0x03 (3),
0x06 (6) and 0x07 (7) can be reset for all modules
simultaneously by means of a maintenance reset (see
on page
A lower threshold (index 0x2432 (8258) subindex 0x01 (1))
and an upper threshold (index 0x2042 (8258)
subindex 0x02 (2)) can be defined for the relative humidity
module. The sensor recognizes when a threshold is
exceeded and sets the Boolean variables for
undershooting the lower threshold (index (0x2043 (8259)
subindex 0x01 (1)) or for exceeding the upper threshold
(index 0x2043 (8259) subindex 0x02 (2)). These Boolean
variables are available in the status bits of the process data
Additionally, the sensor can trigger IO-Link events if a
threshold is exceeded. The sending of events (see
Tab. 6-21 on page 40) for monitoring the humidity can
be switched off (index 0x2042 (8258) subindex 0x03 (3)).
Index
Sub-
index
Access Description
Data
type
Value
range
Default
value
HUMIDITY
1)
0x2041
(8257)
0x01
(1)
Read
only
HUMIDITY – Current value in % RH
float32
0x02
(2)
Read
only
MINIMUM HUMIDITY SINCE STARTUP – Minimum
value since the last startup in % RH
float32
0x03
(3)
Read
only
MAXIMUM HUMIDITY SINCE STARTUP – Maximum
value since the last startup in % RH
float32
0x04
(4)
Read
only
MINIMUM HUMIDITY LIFETIME – Minimum value since
production in % RH
float32
0x05
(5)
Read
only
MAXIMUM HUMIDITY LIFETIME – Maximum value
since production in % RH
float32
0x06
(6)
Read
only
MINIMUM HUMIDITY SINCE RESET – Minimum value
since the last manual reset in % RH
float32
0x07
(7)
Read
only
MAXIMUM HUMIDITY SINCE RESET – Maximum value
since the last manual reset in % RH
float32
HUMIDITY ALARM CONFIGURATION
1)
0x2042
(8258)
0x01
(1)
Read/
Write
LOWER ALARM LEVEL HUMIDITY – Lower threshold
for humidity in % RH
float32
5…95
[% RH]
5 [% RH]
0x02
(2)
Read/
Write
UPPER ALARM LEVEL HUMIDITY – Upper threshold
for humidity in % RH
float32
5…95
[% RH]
95 [% RH]
0x03
(3)
Read/
Write
ENABLE ALARM HUMIDITY – Activates (True) or
deactivates (False) the sending of the IO-Link events
0x8CE5 and 0x8CE6 if one of the thresholds is
exceeded or underrun
bool
True/False
True
HUMIDITY ALARM STATUS
1)
0x2043
(8259)
0x01
(1)
Read
only
LOWER ALARM STATUS HUMIDITY – Lower threshold
underrun
bool
0x02
(2)
Read
only
UPPER ALARM STATUS HUMIDITY – Upper threshold
exceeded
bool
Tab. 6-11: Relative humidity
1)
only for the BCM R15E-
002
-DI00-_ _ , _-S4
1)
BCM R15E-00 _ -DI00-_ _ , _-S4
Condition Monitoring Sensor
Summary of Contents for BCM R15E-00 Series
Page 1: ...BCM R15E 00_ DI00 _ _ _ S4 deutsch Betriebsanleitung english User s guide...
Page 2: ...www balluff com...
Page 3: ...BCM R15E 00_ DI00 _ _ _ S4 Betriebsanleitung deutsch...
Page 4: ...www balluff com...
Page 49: ...BCM R15E 00_ DI00 _ _ _ S4 User s Guide english...
Page 50: ...www balluff com...
Page 95: ......