24
english
6
IO-Link interface (continued)
6.2.4 Operating hours counter
Operating hours (index 0x0057 (87)) are counted since the
last startup (subindex 0x01 (1)), since production (subindex
0x02 (2)) and since the last manual reset (subindex 0x03
(3)).
Index
Sub index
Access
Description
Data type
OPERATING HOURS
0x0057
(87)
0x01 (1)
Read only
OPERATING HOURS SINCE STARTUP – Operating hours since the
last startup. Value in seconds.
uint32
0x02 (2)
Read only
OPERATING HOURS LIFETIME – Operating hours since production.
Value in seconds.
uint32
0x03 (3)
Read only
OPERATING HOURS SINCE RESET – Operating hours since the last
reset of the counter by means of a maintenance reset. Value in
seconds.
uint32
Tab. 6-8: Operating hours counter
6.2.5 Boot cycle counter
The BCM counts every startup (index 0x0058 (88)) since
production (subindex 0x01 (1)) and since the last manual
reset (subindex 0x02 (2)).
Index
Sub index
Access
Description
Data type
BOOT CYCLE COUNTER
0x0058
(88)
0x01 (1)
Read only
BOOT CYCLE COUNTER LIFETIME – Number of application starts
since production
uint32
0x02 (2)
Read only
BOOT CYCLE COUNTER SINCE RESET – Number of application
starts since the last reset of the counter by means of a maintenance
reset
uint32
Tab. 6-9: Boot cycle counter
BCM R15E-00 _ -DI00-_ _ , _-S4
Condition Monitoring Sensor
Summary of Contents for BCM R15E-00 Series
Page 1: ...BCM R15E 00_ DI00 _ _ _ S4 deutsch Betriebsanleitung english User s guide...
Page 2: ...www balluff com...
Page 3: ...BCM R15E 00_ DI00 _ _ _ S4 Betriebsanleitung deutsch...
Page 4: ...www balluff com...
Page 49: ...BCM R15E 00_ DI00 _ _ _ S4 User s Guide english...
Page 50: ...www balluff com...
Page 95: ......