Parameter Descriptions
7-53
H71
Accel/Decel Time Scale
Range:
0 - 2
Default:
1
Access
Tunable
See Also:
P36, P41, P42, H70
This parameter is used to scale the time units for the accel/decel ramp. The
display for the VS1MD is available up to 5-digits. Therefore, if time unit is
set to 0.01 sec for example, maximum accel/decel time would be 600.00
seconds.
H72
Power-On Display
Range:
0 - 9
Default:
0
Access
Configurable
See Also:
d0-d9, H74
This parameter selects the parameter to display on the keypad when power
is applied.
H74
Gain for Motor RPM Display
Range:
1-100 [%]
Default:
100
Access
Configurable
See Also:
d1, H72
This parameter is used to change the motor rpm display to a scaled custom
factor. When H40 = 0 (V/F Control) or 1 (PID Control), the inverter output
frequency is displayed in RPM suing the formula below. Motor slip is not
considered.
0 = Setting Unit: 0.01 sec
Range: 0.01 ~ 600.00
1 = Setting Unit: 0.1 sec
0.1 ~ 6000.0
2 = Setting Unit: 1 sec
1 ~ 60000
0 = Frequency Command
1 = Motor RPM
2 = Output Current
3 = Output Voltage
4 = Output Power
5 = Output Torque
6 = DC Link Voltage
7 = Digital Input Status
8 = Digital Output Status
9 = Software Version
100
74
32
120
H
P
f
RPM
×
⎟
⎠
⎞
⎜
⎝
⎛
×
=
Summary of Contents for VS1MD
Page 2: ...Instruction Manual VS1MD User Manual MN760 3 6 07...
Page 5: ...4 VS1MD AC Drive User Manual...
Page 11: ...1 2 VS1MD AC Drive User Manual...
Page 27: ...4 8 VS1MD AC Drive User Manual...
Page 103: ...7 58 VS1MD AC Drive User Manual...
Page 131: ...8 28 VS1 MD AC Drive User Manual 8 13 Control Block Diagram m G k G h Vk Vm w t t...
Page 133: ...8 30 VS1 MD AC Drive User Manual...
Page 143: ...9 10 VS1 MD AC Drive User Manual...
Page 150: ...Options Kits B 5 B 2 4 VS1MD NM1C B 2 5 VS1MD NM1D...
Page 155: ...B 10 VS1MD User Manual...
Page 167: ...VS1MD User Manual...
Page 168: ......
Page 169: ...Publication MN760 3 2007 Baldor Electric Company All rights reserved...