Customizing for Your Application
8-1
C
HAPTER
8
Customizing for Your Application
8.1
Frequency Mode
8.1.1 Keypad Frequency Setting 1
Note:
When remote keypad is connected, keypad keys on the body are deactivated.
Group
Code
Parameter Name
Setting
Range
Initial
Unit
Drive
group
P37
[Frequency Command]
-
0 to
400
0.00
Hz
P40
[Frequency Setting
Method]
1
1 to 7
1
Step 1. Set
P40
[Frequency mode] to “1”.
Step 2. Set the desired frequency in
P37
and press the Prog/Ent ( ) key to enter
the value into memory.
Step 3. The value can not be set above
P36
[Frequency Hiigh Limit].