8.1.6 Digital outputs - general purpose (non-isolated)
This specification is for the NextMove ES card when used separately or in conjunction with the
optional non-isolating backplane BPL010-501:
Description
Unit
Value
Load supply voltage
(maximum)
V
50
Output current
Max. sink per output, one output on
Max. sink per output, all outputs on
mA
DOUT0-7
DOUT8-11
500
400
150
50
Update interval
Immediate
8.1.7 Digital outputs - general purpose (opto-isolated)
This specification is for the optional opto-isolating backplanes BPL010-502 or BPL010-503,
when used in conjunction with the NextMove ES card.
Description
Unit
Value
USR V+ supply voltage
Maximum
Minimum
VDC
30 V
12 V
Output current
(BPL010-502)
Max. source per output, one output on
Max. source per output, all outputs on
mA
DOUT0-7
DOUT8-11
350
400
75
50
Output current
(BPL010-503)
Max. sink per output, one output on
Max. sink per output, all outputs on
mA
DOUT0-7
DOUT8-11
500
400
150
50
Update interval
Immediate
Switching time
No load on output
With 7 mA or greater load
100 ms
10
μ
s
8.1.8 Digital output - error output (non-isolated)
This specification is for the NextMove ES card when used separately or in conjunction with the
optional non-isolating backplane BPL010-501:
Description
Unit
Value
Output voltage
V
5
Output current
(maximum)
mA
100
Update interval
Immediate
Servo Systems Co. • 115 Main Road • P.O. Box 97 • Montville, NJ,
07045-0097 • (973) 335-1007 • Toll Free: (800) 922-1103
Fax: (973) 335-1661 • www.servosystems.com