10
OWNER’S MANUAL |
THERMOMASSEUR
®
1 800 463.2187
From 8 a.m. to 8 p.m. Monday to Thursday (EST) . From 8 a.m. to 5 p.m. on Friday (EST)
Printed in Canada. Copyright © May 2017 BainUltra Inc. All rights reserved. 45220001
Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents.
THERMOMASSEUR
®
THERMOMASSEUR
®
PLUMBING INSTALLATION
All plumbing installations must be carried out by a
certified plumber. Installation of a ThermoMasseur
®
is the same as for regular acrylic baths. Pay close
attention to the following when installing the
ThermoMasseur
®
:
Once the plumbing installation is complete and
before tile or any other related work begins, fill the
bath to the overflow and wait thirty minutes. Check
all plumbing hook-ups and bath for leaks.
BainUltra
®
is not responsible for any water damage
caused by leaks due to improper installation (see
WARRANTY section)
.
LEAK TEST
The drain and overflow openings are factory-drilled.
However, drilling may be necessary to install faucets.
This drilling of acrylic is a very delicate operation.
DRILLING ACRYLIC FOR FAUCETS
1. DRILLING
1-1
Drill a 1/16” guide hole before using the
hole saw.
1-2
Use a hole saw in good condition to avoid
accidental scratches. The center guide
bit should extend 1/4” (0.6 cm) for correct
drill positioning.
1/4
”
[0.6 cm]
1-2
1-1
1/16
”
IMPORTANT
• Do not remove the protective plastic film (peel coat) on the bath and place a drop-cloth in the
Thermomasseur
®
during installation to protect acrylic.
• To avoid drilling in an air intake zone or, an electric component, always check under deck
before drilling.
• Drill openings slightly larger than actual faucet size. This is to avoid any possible cracking or
other damage to the acrylic.
• When installing faucets, do not over-tighten fittings, as this may damage the acrylic.
• This type of damage is not covered by the warranty.
• Drill at medium speed and do not apply pressure to drill; let the drill do the work.
• The temperature of the water heater should not exceed preset and/or recommended levels by the
manufacturer. This may cause a thermal shock to the acrylic and will not be covered by the warranty.
THERMOMASSEUR
®
- PLUMBING INSTALLATION