![Badger Meter ModMAG M Series User Manual Download Page 65](http://html1.mh-extra.com/html/badger-meter/modmag-m-series/modmag-m-series_user-manual_3659202065.webp)
M2000 Transmitter Dimensions
in. (mm)
3.90 (99)
7.09 (180)
7.09 (
18
0)
M
20
(x
3)
11.06 (
28
1)
M
20
00
-1
2.36 (
60)
Ø 0.20 (
5.2)
2.56 (65)
Sensor Type II Specifications
The electromagnetic sensor type II is not only available in a number of different flange process connections (DIN, ANSI, JIS,
AWWA, and more) but also in a number of liners like hard rubber, PTFE, PFA, or Halar . The sensor is configurable with up to
4 electrodes for measuring, empty pipe and grounding electrodes . Available in sizes from DN 6 TO DN 2000 and nominal
pressures up to PN 100, the sensor type II is best suited for a variatey of applications in the industry and the water/waste
water industry .
Size
1/4…78 in . (DN 6…2000)
Flanges
ANSI B16 .5, AWWA, ISO 1092-1, JIS and more in carbon steel . Optional 304 or 316 stainless steel .
Nominal Pressure
up to 1450 psi (100 bar)
Pressure Rating
Line sizes 1/4…24 in . In accordance with ASME B16 .5 Class 150 or Flange Rating Class 300
Line sizes 26…72 in . AWWA C-207 Class D or Class E Flange Rating
Protection CLass
NEMA 4X (IP67), optional NEMA 6P (IP68)
Minimum Conductivity
5 µS/cm (20 µS/cm for demineralized water)
Liner Material
Hard/soft rubber
1…78 in . (DN 25…2000)
32…176° F (0…80° C)
PTFE
1/2…24 in . (DN 15…600)
–40…302° F (–40…150° C)
Halar (ECTFE)
12 in . (DN 300) and larger
–40…302° F (–40…150° C)
PFA
1/4…3/8 in . (DN 6…10)
—
Electrodes Materials
Hastelloy C (standard), Tantal
Platinum/Gold plated, Platinum/Rhodium
Housing
Standard:
Carbon steel welded;
Optional:
316 or 304 stainless steel
Electrode Materials
Standard:
Hastelloy C22;
Optional:
316 stainless steel, gold/platinum plated, tantalum, platinum/rhodium
Lay Length
1/4…3/4 in . (DN 6…20)
6 .7 in . (170 mm)
1…2 in . (DN 25…50)
8 .9 in . (225 mm)
2-1/2…4 in . (DN 65…100)
11 .0 in . (280 mm)
5…8 in . (DN 125…200)
15 .8 in . (400 mm)
10…14 in . (DN 250…350)
19 .7 in . (500 mm)
16…28 in . (DN 400…700)
23 .6 in . (600 mm)
30…40 in . (DN 750…1000)
31 .5 in . (800 mm)
48…56 in . (DN 1200…1400)
39 .4 in . (1000 mm)
64 in . (DN 1600)
63 .0 in . (1600 mm)
72 in . (DN1800)
70 .9 in . (1800 mm)
78 in . (DN2000)
78 .7 in . (2000 mm)
Sensor Type II DimensionsSensor Type II Specifications
The electromagnetic sensor type II is not only available in a number of different flange process connections (DIN, ANSI, JIS,
AWWA) but also in a number of liners like hard rubber, PTFE, PFA, or Halar . The sensor is configurable with up to 4 electrodes
for measuring, empty pipe and grounding electrodes . Available in sizes from DN 6 TO DN 2000 and nominal pressures up to
PN 100, the sensor type II is best suited for a variety of applications in the industry and the water/waste water industry .
Specifications
Page 65