PROGRAMMING THE M2000 METER
The M2000 transmitter comes pre-programmed from the factory . Typically, you do not need to do any additional
programming . However, to take advantage of special features, you can program the meter for your specific needs . If you are
programming the meter, familiarize yourself with the Function Buttons and Displays, and follow the procedures outlined in
this manual .
Function Buttons
All M2000 meter programming is accomplished using the three function buttons located on the front of the transmitter:
Figure 26: Function buttons
OTE:
N
Throughout this manual, the buttons are referred to as: [
↑
] or [
+
] and [
↓
] or [
–
], depending on the context . The “Enter”
button is referred to as [
E
] .
Consider the Up Arrow [
+
|
↑
] button as the “next step” or “scroll text up” button . During programming, press this
button to display the next menu selection or increment a numeral .
Example 1:
shows the
Start Menu
. The selection arrow points to the
Exit this Menu
selection .
To scroll up to the next selection, press [
↑
] once . The menu text scrolls up to the next menu selection,
Main Menu
.
START MENU
>Exit this Menu
Main Menu
MORE:
↑
,
↓
ENTER:>
Press [
↑
]
START MENU
> Main Menu
Quick Setup
MORE:
↑
,
↓
ENTER:>
Figure 27: Scroll up
Example 2:
Some procedures require you to enter a numeric value . Use the [
+
] button to increment the selected numeral .
shows the
Low Flow Cutoff
parameter display . Notice the cursor under the 2 . In this case, press [
+
] once to increment
the numeral to the value of 3 .00% .
LOW FLOW CUTOFF
% of 300.000 GPM
2.00%
CHG: +,- NEXT:E
Press [+]
LOW FLOW CUTOFF
% of 300.000 GPM
3.00%
CHG: +,- NEXT:E
Figure 28: Enter a numeric value
Consider the Down Arrow
[
–
|
↓
] button as the “previous step” button . During a procedure, press this button to return
to the previous selection or decrement a numeral .