Wiring for Remote Configuration
CONNECT OR SEPARATE SIGNAL CONNECTION CABLE ONLY WHEN THE UNIT HAS BEEN SWITCHED OFF.
From
Detector
To Amplifier
13 Shield
12 Coil
11 Coil
44 Shield
40 Empty Pipe
44 Shield
46 Electrode
44 Shield
45 Electrode
Junction Box
M2000 Amplifier
CS C2 C1
E1
ES
E2
RS
EP
ES
11 Coil
12 Coil
13 Shield
Shield (cut off)
Green (11)
Yellow (12)
Black (13) Overall Shield
45 Electrode
44 Shield
46 Electrode
44
40 Empty Pipe
44 Shield
White (45) Electrode
Black (44) Shield
Brown (46) Electrode
Pink (40)
Black (44) Shield
Gray (cut off)
Gray (cut off)
Black (44) Shield
Pink (40)
Brown (46) Electrode
Black (44) Shield
White (45) Electrode
Black (13) Overall Shield
Yellow (12)
Green (11)
Shield (cut off)
Figure 20: Wiring for remote configuration
Remote style M2000 transmitter models can be ordered with standard cables measuring 15, 30, 50,100 and 150 feet . In
addition, cables up to 500 feet are available .
From Junction Box
To M2000
Transmitter
Connection No.
Description
Wire Color
Connection Label
11
Coil
Green
C1
12
Coil
Yellow
C2
13
Main Shield
Black (Red Ferrule)
CS
45
Electrode
White
E1
44*
Electrode Shield
Black
ES
46
Electrode
Brown
E2
40
Empty Pipe
Pink
EP
44*
Empty Pipe Shield
Black
ES
*Connections with the No . 44 are lying on the same potential .
Empty Pipe Detection Considerations
Take into account the following cable length and conductivity requirements if you are using empty pipe detection .
Cable Length (Feet)
Minimum Conductivity Required (µS/cm)
0*
5
100
20
500
100
* Meter Mount
Wiring
Page 20
March 2022
MAG-UM-01272-EN-21