Communication
Diagnostics
Port A
Counters
[0]
S
Port counters are used for diagnostics when configured for Modbus RTU . These counters
are only cleared on power up .
Counter
Description
Pkts Processed Number of packets processed by meter .
Broadcast Pkts Number of broadcast packets (address = 0) processed by meter .
CRC Errors
Number of received packets with CRC error; packet is discarded .
Pkts Rcvd
Number of packets received with an address of the configured
port address .
Pkts Sent
Number of packets transmitted in response to a received packet .
Parity Errors
Number of characters with parity errors (
for example, if the
received
character has a mismatch between the number of 1s and its parity bit);
packet is discarded .
Framing Errors Number of characters with framing errors (for example, stop bit is not
found – indicates that synchronization with the start bit has been lost
and the character is improperly framed); packet is discarded .
Overrun Errors Number of characters received that were not processed due to
degradation of system performance .
Break Detects
Number of detections that transmission line is locked (
for example,
the
receive line is low for 10-bit transmissions following a missing stop bit) .
Port B
Counters
[0]
S
Daughterbrd
config.
Parameter
Value Description
BACnet MS/TP Baud
9600 Baud Rate of the BACnet MS/TP network . Common settings would be
9600, 19200, 38400, and 76800 .
BACnet MS/TP MAC ID 1
Sets BACNET MS/TP Device ID of module/meter . Max value = 127 .
BACnet Max Master
127
Sets the max master variable for the device . Max value = 127 .
BACnet Instance
10001 Sets the BACnet Instance number . The instance number is an unsigned
decimal number that can range from 0 to 4,194,302 . Every device on a
BACnet network gets an instance number, and two devices must not have
the same number .
Advanced
Data Logger
OTE:
N
This
feature needs an
additional memory
token that is not
included with the
standard meter
The Data Logger feature requires firmware version 1 .10 or later . Reference Badger Meter
P/N 67354-003 to obtain a firmware upgrade kit . See the
M2000 Data Logging
user manual, available
at
, for details on this feature .
The Data Logging feature records three types of events to a memory token:
• Totalizer/error events
• Configuration change events
• Startup events (power up, power down or reset events)
Token Copy
OTE:
N
This
feature needs an
additional memory
token that is not
included with the
standard meter
• Configuration
• Store to Token
• Restore to Token
See the
M2000 Store/Restore
user manual, available at
, for details on using the Token Copy features .
Using the Main Menu Programming Options
Page 48
March 2022