66
BTEK T403S Indicator User Instructions
Supervisor menu
14.
Press
UNITS
to scroll through the choices and when your choice is displayed,
press
ZERO
to accept …
PrEAct
is displayed.
Negative fill
Batch
Type
Mode
Display
Preact
Negative Fill
15.
Press
UNITS
…
NEG FiL
is displayed. This stands for negative fill. This has two choices:
oFF
or
on
. Each is explained below:
Choose
oFF
to disable negative fill. (default)
Choose
on
to enable negative fill. Operation varies depending on Type
chosen. See
16.
Press
SELECT
…
The current setting is displayed.
17.
Press
UNITS
to scroll through the choices and when your choice is displayed,
press
ZERO
to accept …
NEG FiL
is displayed.
18.
Press
TARE
…
bAtch
is displayed.
19.
Press
UNITS
…
bAttErY
is displayed. The battery menu is identical in all the
applications. Refer to step
for information on setting up the
battery.
20.
This completes the Supervisor menu for the Batching application. Repeatedly
press
TARE
until the indicator returns to normal weighing mode.
The current weight value is displayed.
7.5.2 Notes on batching
2 Speed
MODE
setting does not apply to 2 SPEED.
If
DISP
is set to
NET
, an autotare will occur prior to the start of the fill.
If
DISP
is set to
GROSS
,
no autotare will occur and the fill cutoffs are based on
actual Gross weight.
PREACT
, if used, only affects the cutoff value of Out 2. See details of
PREACT
below.
If
NEG FILL
is set to
YES
, then
DISP
should be set to
NET
so that an autotare
occurs prior to start and the cutoffs will be based on negative entered values for
Out 1 and Out 2.
Summary of Contents for T403S
Page 1: ...T403S Indicator User Instructions AWT35 501633 Issue AA ...
Page 2: ...BTEK_T403S_u_en_501633 book 2016 B TEK All rights reserved ...
Page 72: ...72 BTEK T403S Indicator User Instructions Supervisor menu ...
Page 73: ......
Page 74: ...B TEK Scale LLC 1510 Metric Ave SW Canton OH 44706 3088 ...