BTEK T403S Indicator User Instructions
21
3.3 Counting application
b
If the sample size was not large enough or if the weight was unstable,
Abort
is displayed and the display returns to gross weighing mode.
Repeat steps
using a larger sample size.
6.
Place the parts on the scale to be counted. To accumulate the count and
number of transactions, press
while in count mode.
7.
If enabled, press and hold
for three seconds to print and/or clear the
active count total. These functions are enabled or disabled in a password
protected menu.
3.3.6 Piece weight entry
Piece weight can be entered manually.
1.
Press and hold
SAMPLE
.
The current piece weight is displayed.
2.
Key in a new value and press
ZERO
to accept.
Minimum sample weight is the gross zero band value. The initial sample count is 5
pieces. The maximum number of pieces that can be sampled is 100,000.