6.
Place a weight on the scale …
If the weight is below the lower accept weight, the left bargraph
segments will light.
Any weight between the lower and upper acceptable weights will cause
the middle bargraph segment to light to show the weight is within the
target range.
If the weight is above the upper acceptable weight, the right bargraph
segments will light.
7.
Remove the item from the scale and repeat step
to check other items.
8.
To set new upper and lower limits, repeat steps
3.4.6 Setpoint operation in the checkweighing application
Inside the Gross Zero Band
= All outputs and annunciators are off.
Under Target or Below Low Accept Weight
=
SP1
annunciator and Output 1 are on.
Inside Target
=
SP2
annunciator and Output 2 are on.
Over Target or Above Upper Accept Weight
=
SP3
annunciator and Output 3 are on.
Outputs can be set as latched or unlatched in a password protected menu.
If outputs are unlatched
The annunciators and outputs follow the status of
the bargraph except in gross zero band.
If outputs are latched
The annunciators’ and outputs’ status is
determined by where the first stable weight
occurs after an item is placed on the scale. The
latched annunciator and output is reset OFF only
when weight returns inside the gross zero band.
Outputs have to be enabled (see Service manual).
Contact technical support for information about setpoint use with battery operated
scales.
Summary of Contents for T403S
Page 1: ...T403S Indicator User Instructions AWT35 501633 Issue AA ...
Page 2: ...BTEK_T403S_u_en_501633 book 2016 B TEK All rights reserved ...
Page 72: ...72 BTEK T403S Indicator User Instructions Supervisor menu ...
Page 73: ......
Page 74: ...B TEK Scale LLC 1510 Metric Ave SW Canton OH 44706 3088 ...