BTEK T403S Indicator User Instructions
65
7.5 Batching application supervisor menu
Display
Batch
Type
Mode
Display
9.
Press
UNITS
…
diSP
is displayed. Display has two choices:
NEt
or
GroSS
. Each is
explained below:
NEt
Choose Net to base batching on net weights.
GroSS
Choose Gross to base batching on gross weights.
10.
Press
SELECT
…
The current setting is displayed.
11.
Press
UNITS
to toggle between the choices and when your choice is
displayed, press
ZERO
to accept …
diSP
is displayed.
Preact
Batch
Type
Mode
Display
Preact
12.
Press
UNITS
…
PrEAct
is displayed.
Preact can be used to compensate for product weight that continues to
fill into the bag or container after the setpoint output turns off and before
the final weight stabilizes. If a preact value is automatically calculated or
manually entered, the actual cutoff weight will equal the entered setpoint
value minus the preact value.
PrEAct
has three choices:
Manual
,
Auto
, or
cLEAr
. Each is explained
below:
Manual
When
Manual
, the preact values entered in the SETPNT
submenu for PREACT 1, 2 and 3 are used.
Auto
When set to
Auto
, preact is automatically calculated. The
amount of compensation is calculated based on the average
variance between the entered setpoint value and the actual
fill weights recorded during the most recent batch cycles.
Auto Preact is only available in certain Batch Types as
noted in their descriptions. Calculated Preact values can be
viewed in the SETPNT submenu for PREACT 1, 2 and 3.
cLEAr
When
cLEAr
is selected, the current preact values will be
set to 0. If
PrEAct
was set to
Auto
, a new set of
compensation values will be calculated on continuing
batches. If preact was set to
oFF
, then preact will be
disabled or new values can be manually entered in the
setpoint menu.
13.
Press
SELECT
…
The current setting is displayed.
Summary of Contents for T403S
Page 1: ...T403S Indicator User Instructions AWT35 501633 Issue AA ...
Page 2: ...BTEK_T403S_u_en_501633 book 2016 B TEK All rights reserved ...
Page 72: ...72 BTEK T403S Indicator User Instructions Supervisor menu ...
Page 73: ......
Page 74: ...B TEK Scale LLC 1510 Metric Ave SW Canton OH 44706 3088 ...