MANHATTAN Heated Servery Counter
– 46 –
Maintenance
Having unit regularly maintained
B.PRO recommends having regular maintenance performed on the unit
by appropriately trained experts. Regular maintenance prevents failure of
the unit, extends its operating life and contributes to general value
retention.
Having unit regularly maintained by appropriately trained experts.
Checking castor brakes
Unit model with castors
The castor brakes must be checked for effectiveness every time the unit
is moved to a new location.
Lock the castor brakes.
Try to move the unit (do not use force!).
If the effectiveness of the brakes is not sufficient, have the defective
castor(s) replaced immediately by one of the following:
In-house, by B.PRO-trained experts
Externally, by B.PRO-trained customer service
B.PROService
Having periodical electrical safety
inspection carried out
At least once every six months, have a periodical electrical safety
inspection carried out by a professional electrician in accordance with the
DIN VDE 0701–0702 series of standards.
Checking connection cable and
power plug
At least once every six months, check the connection cable and mains
plug for mechanical damage and signs of excessive ageing in
accordance with BGV A 3 or the corresponding national regulations.