Model: MVC10A/10F - Multivariable Air Flow Meter
4-10:
Details of default settings
The items and values that are initially set before shipping from the factory are as
follows:
Setting item
Set value
Main Disp
Total Volume
Unit
Total Volume
m
3
Flow Rate
Nm
3
/h
Total Cost
yen
Cost
yen/h
Damping Time
1.0 s
LowFlow Cut
3%
Leak
Check
Set. Press
0.65 MPaG
TAG
XXXXXXXX
Ref. Temp
0°C
Ref. Pressure
101.325 kPa (abs)
Pulse Weight
Customer-specified value (When unspecified: 0.1 m
3
/pulse)
Cost Rate
0 yen/m
3
Max Flow
Customer-specified value (When unspecified, maximum
value for the given bore)
Language
Japanese