73
AXOR Industries
Service Manual
NanoMack
®
ver.1 rev.11/'19
Inputs time requirements:
CK/DIR Signal
Max. allowable input frequency
Minimum required time width [μs]
t
Line Driver
500kHz
2
Open Collector
200kHz
5
Phase A
Phase B
t t t t
t t t t
Phase B advanced by
90 deg from phase A
Phase B delayed by
90 deg from phase A
Signal
CK
DIR
Positive command
Negative command
4.7 Gearing