![AXOR Industries MACK NANO Service Manual Download Page 12](http://html1.mh-extra.com/html/axor-industries/mack-nano/mack-nano_service-manual_3041271012.webp)
12
AXOR Industries
Service Manual
Nano Mack
®
ver.1 rev.11/'19
1.3 Technical Data
EXTERNAL FUSE PROTECTION
MKN 60
MKN 110
MKN 140
Power Line
F1
RMS * 135%
(next commercial standard - T-type)
Backup
F2
1A / 250V
(T-type )
Dumping resistor
F3
5A / 250V
(T-type )
T-type = time-lag.
AMBIENT CONDITION
During
operation
Temperature
From
+5°C
to
+40°C
(without condensation) [Class 3K3 according to EN
60721-3-3].
From
+40°C
to
+55°C
the drive must be derated 2.5%/°C in reference to
nominal and peak current.
Humidity
From
5%
to
85%
(without condensation) [Class 3K3 according to EN
60721-3-3].
Vibration
Class 3M1 according to EN 60721-3-3.
During
transport
Temperature
From
-25°C
to
+70°C
[Class 2K3 according to EN 60721-3-2].
Humidity
Relative humidity max
85%
(without condensation)
[Class 2K3 according to EN 60721-3-2].
Vibration
Class 2M1 according to EN 60721-3-2.
During
storage
Temperature
From
-20°C
to
+55°C
[Class 1K3 according to EN60721-3-1].
Humidity
Relative humidity from
5%
to
85%
(without condensation) [Class 1K3
according to EN 60721-3-1].
Vibration
Class 1M1 according to EN 60721-3-1.
CONTROL SIGNALS
Digital inputs
+24Vdc - 7mA (PLC compatible)
Digital/Analog outputs
+24Vdc - 20mA (PLC compatible)
Clock/Dir digital inputs
+5 -
differential mode
- Max. Frequency 500kHz
+24V -
common mode
- Max. Frequency 100kHz
Differential analog inputs
(An.IN 1 + / -)
±10V (±5%) - 12bit
Common analog inputs
(An.IN Ref.Torque)
±10V (±5%) - 12bit